ENGLISH
4
PURLIN INSTALLATION
Technical details to be taken into account before starting purlin assembly:
• Follow the instructions in the figures below exactly;
• Use a chalk line to trace the slope from post 4 to post 3.
• Fix the brackets under each purlin. One at a height of 2093 mm and the other at a height of
2066 mm.
Post 4
Position the 2 intermediate purlins (pieces G) in the metal support (pieces S).
ITEM
DESCRIPTION
S
Purlin support
G
Intermediate purlin
2066
2093
G
G
38
Post 1
S
DIMENSIONS (MM)
40 mm
40 x 140 x 3900 mm
QTY
4
2