1 • geNeral saFeTy iNFormaTioN BEWARE: It is prohibited for unqualified personnel to carry out any kind of assembly, repair or adjustment to the apparatus, or if the
eN
necessary precautions haven't been taken, with the power supply disconnected (including any back-up batteries), in order to avoid possible accident or injury. DASPI will not be
responsible for any damage or injury to persons, animals or objects resulting from improper use of the apparatus or for use other than that specified in this instruction booklet,
and/or any random modifications carried out on this product and its components. This product is not suitable for installation in an explosive atmosphere. Look after this manual carefully,
attaching it to the technical installation booklet and keeping them both in a suitable place, ensuring that its whereabouts are known to all personnel who may need to use it in the future.
2 • producT Type The GIGA 3ERX433 electronic unit has been designed to operate two motors for sliding gates (for a one gate motor it is necessary to use the GIGA1ERX433 unit) and is
supplied with an electronic clutch and has a radio receiver incorporated. DASPI accepts no responsibility for use other than that for which the GIGA 3ERX433 unit is intended.
3 • 1.descripTioN oF The adjusTmeNT Trimmers
Tr1
Motor 1 force
Motor 2 force
Tr2
Tr3
Motor 1 slowing down speed
BuTToN descripTioNs:
p1: to enter the program for the path of motor 1 and motor 2
p2: to configure or cancel a radio controlled button on output WARNING LIGHT
p3: to configure or cancel a radio controlled button on sequential output (SEQ/START) or pedestrian (CH/P)
4 • programmiNg aNd adjusTmeNT oF The elecTroNic card
dip1
1
3 second flashing light enabled
2
Resident function enabled
3
Automatic re-closing enabled
Release stroke enabled
4
5
Immediate re-closing after disengaging the two photocells
6
Obstacle detection also when slowing down
Ohmic sensitive edge
7
8
Opening/closing security stop operation
N.B. if inputs which are normally closed are not being used (N.c.), they should be bridged. If several N.C. contacts are used on the same terminal, they should be connected in series. If several
N.A. contacts are used on the same terminal, they should be connected in parallel.
1
M2 Output Motor2 24 V DC.
2
3
M1 Output Motor1 24 V DC.
4
5
LAMP Flashing light output: intermittent output 24V DC max 10W
6
7
COURT Courtesy light output, switched on for 60 seconds from the end of the
8
cycle (24V DC max 10W)
K OPT WARNING LIGHT output (2nd channel), clean contact. Fast flashing
when closing, slow when opening, fixed with gate open, off when gate
9
closed. Possibility of inverting the contact status from N.C. to N.O. via
10
the jumper JP1(maximum applicable voltage 3A 24V DC or 2A 125V DC) if
programmed, functions as second radio channel output
SERR 12V LOCK output. Is activated on opening for 1 sec (If DIP4 = ON
11
the gate pushes shut), then remains activated for 1 sec at the start of
12
opening.(12V DC, 15VA)
13
24Vdc Output 24 V DC photocell accessory supply. 13 - / 14 + (max 500mA)
14
15
FCC2 Input for motor 2 closing stop mechanism
17
N.C. contact
16
FCA2 Input for motor 2 opening stop mechanism
17
N.C. contact
18
FCC1 Input for motor 1 closing stop mechanism
17
N.C. contact
19
FCA1 Input for motor 1 opening stop mechanism
17
N.C. contact
led signalling of the electronic card inputs (verifiable after switching on the power supply to the unit)
dl1
OPEN: Always switched off, lights up with the command OPEN
dl2
CL/P Always switched off, lights up with the command PEDESTRIAN
dl3
SEQ: Always switched off, lights up with the command START
dl10
STOP: Always lit, switches off with the intervention of STOP
dl11
PHOTO: Always lit, switches off with the intervention of PHOTOCELL CLOSING
oN
Tr4
Motor 2 slowing down speed
Automatic closing time from 2 to 120 seconds
Tr5
Tr6
Motor speed before slowing down
No flashing light
Resident function disabled
Automatic re-closing disabled
Disabled
Disabled
Disabled
Mechanically sensitive edge
Only when opening
SENSITIVE EDGE (BORDO) Sensitive edge output. If DIP8 = OFF partial
20
reverse operation when gate opening; if DIP8 = ON partial reverse
21
operation when gate opening or closing, with dip 7: ON controls resistive
edge OFF mechanical edge
20
PHOTO IN Opening photocell: stops movement when opening and closing.
22
The gate re-opens when contact is resumed.
17
PHOTO Closing photocell: stops and changes wing movement during
18
closing.
STOP Emergency stop. When the contact opens it blocks the movement
20
of the wings and inhibits automatic re-closing. The unit does not accept
23
commands until the contact remains open. On restoring operation,
opening is always the first manoeuvre (with stop mechanism used)
24
SEQ (START) controls the start of the 2 motors, with the following cyclic
25
sequence: open, stop, close and open.
27
CH/P controls the start of motor 1, with the following cyclic sequence:
26
open, stop, close and open
OPEN Button for opening, only controls the opening of the 2 motors. If
24
pressed for the entire gate opening time, functions like a clock (contact
28
closed gate open, contact open controls the immediate closure of the
gate)
29
M4 Connectors for accessories in bus communication (only use with bus
30
Bus
accessories) or to update software. 29- 30BUS 31+
31
32
M3 Antenna connectors: 32 display, 33 signal
33
cN3
CN3:Connector for motor 2 encoder (if provided in the motor)
cN4
CN4: Connector for motor 1 encoder (if provided in the motor)
dl14
PHOTO IN: Always lit, switches off with the intervention of PHOTOCELL OPENING
dl15
OSM1:Always lit, switches off with the intervention of OPENING STOP MECHANISM
OF M1
dl12
CSM1:Always lit, switches off with the intervention CLOSING STOP MECHANISM
OF M1
dl13
OSM2:Always lit, switches off with the intervention of OPENING STOP MECHANISM
OF M2
dl16
CSM2: Always lit, switches off with the intervention of CLOSING STOP MECHANISM
OF M2
oFF