Thank you for buying this product, our company is sure
that you will be more than satisfied with the product's
performance. The product is supplied with a "Warnings"
leaflet and an "Instruction booklet". T hese s hould b oth
be read carefully as they provide important information
about safety, installation, operation and maintenance.
This product complies with the recognised technical
standards and safety regulations. We declare that this
product is in conformity with the following European
Directives: 2004/108/EEC and 2006/95/EEC (and subse-
quent amendments).
GENERAL SAFETY
WARNING! An incorrect installation or improper
use of the product can cause damage to persons,
animals or things.
• Scrap packing materials (plastic, cardboard,
polystyrene etc) according to the provisions set out
by c urrent s tandards. K eep n ylon o r p olystyrene b ags
out of children's reach.
• Keep the instructions together with the technical
brochure for future reference.
• This product was exclusively designed and ma-
nufactured for the use specified in the present
documentation. Any other use not specified in this
documentation could damage the product and be
dangerous.
• The Company declines all responsibility for any
consequences resulting from improper use of the
product, or use which is different from that expected
and specified in the present documentation.
• Do not install the product in explosive atmosphere.
• Disconnect the electrical power supply before
carrying out any work on the installation. Also di-
sconnect any buffer batteries, if fitted.
• Only use original parts for any maintenance or repair
operation.
• Instruct the product user about the control systems
provided and the manual opening operation in case
of emergency.
• Do not allow persons or children to remain in the
automation operation area.
• Keep radio control or other control devices out of
children's reach, in order to avoid unintentional
automation activation.
• The user must avoid any attempt to carry out work or
repair on the automation system, and always request
the assistance of qualified personnel.
• Anything which is not expressly provided for in the
present instructions, is not allowed.
• Fit a n o mnipolar o r m agnetothermal s witch o n t he m ains
power supply, having a contact opening distance equal
to or greater than 3,5 mm.
• Check t hat a d ifferential s witch w ith a 0 .03A t hreshold
is fitted just before the power supply mains.
• The p ower s upply m ust h ave a v ery l ow s afety v oltage
and the generator must be protected against short
circuit.
1) GENERAL OUTLINE
Programmable digital pushbutton panel for control-
ling pedestrian and vehicle access points using two
operating methods:
1 - Serial connection:
Manages control panels provided with serial con-
nection.
10 - Q.BO PAD
INSTALLATION MANUAL
Up to 16 different codes can be memorised. Each
valid code sends a start command through the serial
line.
2 - Interfaced with a Compass system:
The pushbutton panel is integrated in the Compass
access control system.
Provided with an anti-break-in metal container,
the Q.BO PAD pushbutton panel does not directly
control access point opening. Therefore, it can also
be safely installed in unprotected areas.
2)TECHNICAL SPECIFICATIONS
Power supply: ...........................12/24 V
Absorption: ..................................................................... 60 mA
Working temperature: ...................................... -10 / +55°C
No. codes (serial connection): .......................................... 16
Dimensions: ................................................................see Fig.A
Degree of protection: .....................................................IP 44
3) INSTALLATION
Use the box as a drilling template and drill 4 holes. Fix
by means of self-tapping screws or expansion plugs,
depending on the surface the box is being fixed on.
Use the black sponge (H, Fig.A1) between the appliance
and the wall (Fig.A1).
1) Proceed to wiring and fixing the electronic board
by means of the 2 screws supplied as standard, as
shown in F ig.B1. Fully t ighten the screws, and c orrect
any centring errors using the slots in the board.
Correct board positioning is obtained by means of
the connection terminal bar, positioned as shown
in Fig.B1.
2) Position the gasket and ring nut, as shown in Fig. B2,
and proceed to fixing using the 4 screws supplied.
3) Attach t he m etal b utton u nit a fter r otating i t b y a bout
30° anticlockwise, as shown in Fig.B3.
4) Use t he s pecial a nti-break-in s etscrew w rench s upplied
and loosen the dowel until it is secured t o t he b ottom
of the push-button board (Fig.B4).
4) CONNECTION DIAGRAM
WARNING! In case the power is supplied by an external
generator, it should feature a very low safety voltage
and the generator be protected against short-circuit
and overloading.
JP1
1-2 Power supply input 12/24 V
3-4
5-6
5) DIP-SWITCHES
DIP 1
ON
- Connected to COMPASS system
The code is transmitted through outputs 5/6 to a
COMPASS system for subsequent check and activation.
OFF
- Serial operation
The e ntry o f a v alid c ode, p rogrammed i n t he p ushbutton
panel internal memory, causes a Start signal to be sent
through serial output TX1-TX2.
~
1 - + 12/24 V
/
2 - 0 V
Serial output towards control panels:
3-TX1 4-TX2
Data output for connection to Compass:
5-DØ
6-D1
~
/
±10% 50Hz
~
/
±10% 50Hz