Use
Assembly
NOTE
Refer to Fig. IPB 1, page 8 for
component identification on all
assembly procedures
NOTE
Select a clean environment for all
assembly procedures Prevent
contamination from foreign material
Damage to components can occur
NOTE
Make sure to remove protective cover
from inlet of pump (1)
Do not apply thread sealant to the first
two threads of any connection
Contamination can occur
1 Screw union adapter (6) with thread
sealant into adapter (5) as required
2 Tighten union adapter securely
3 Screw into pump outlet
4 Install pump (1) into cover (7)
5 Secure pump to cover with washers (8),
lock washers (9), and cap screws (10)
6 Tighten cap screws securely
7 Place follower plate (12) onto top of
product
8 With a wobbling motion, eliminate any
air that may be trapped underneath
follower plate Force product through
hole in center of plate
9 Guide pump tube into follower plate and
fit cover onto container
10 Secure cover to container with thumb
screws (11)
11 Test/prime pump Refer to manual
670629 for details