adjust your setting temperature as you like.
If the RF signals weren't received correctly,
check the installation (Position, distance...)
or restart the RF pairing rules to be sure.
You may have to use a Watts RF repeater if
you want to extend the RF range.
Please note that direct radio pairing
between the SH-RC and a SH-AT or SH-DT
room control unit is not possible. If you want
to use an SH-AT or SH-DT room operating
unit in a room, you should pair it with the
SH-CU central unit. Then pair one or more
SH-RC with the central unit.
4.2 Starting
The thermostatic head is now ready to
work with the Central Unit. The default
working mode will be the mode imposed
by the Central Unit.
In case of Automatic mode
gram can be changed from the thermostatic
head, the program is directly set inside the
Central Unit (see Central Unit leaflet). The
Setting View
Clock View
36
following screens can be viewed:
Note: the time will be also sent by the
Central Unit, then all your installation will be
synchronized with the same time.
At any time, when the backlight is off,
press any key to light-up the backlight,
and then press another time the ( ) key
to switch the view between the setting
temperature and the time values. The days
are not shown anymore as no programma-
tion is available in the thermostatic head.
Programmation is only possible inside the
Central Unit.
4.3
With the Central Unit, the Clock update
and program modes are note available
anymore as setting time values and pro-
gram values are directly configured in the
, no pro-
Central Unit.
The following modes are available; refer
to stand-alone version chapters for more
explanations
Timer / Booster mode
Manual mode, comfort
The thermostatic head will follow the pro-
gram selected on the Central Unit.
Manual mode, reduced
Manual mode, Antifreeze
The anti-freeze temperature is set by the
Central Unit (see the leaflet of the Central
Unit to change the anti-freeze value of your
installation)
OFF mode
Working modes
Automatic mode
GB