Descargar Imprimir esta página

Energizer Solar Peak 1800 Manual Del Usuario página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

ENERGIZER SOLAR PEAK 1800
Icon
Icon Characteristics
Error code always on
Low Temperature icon
flashes / Error code
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
High Temperature icon
flashes / Error code
High Temperature icon
flashes / Error code
High Temperature icon
flashes / Error code
High Temperature icon
flashes / Error code
Error code always on
USB-A icon flashes / Error
USB-C icon flashes / Error
Error code always on
If there is a warning occurs during the use of this product, and the warning icon still does not disappear after restarting
the device, please stop using it immediately (do not try to charge or discharge). If none of the above information can solve
problem you encounter, please contact Energizer Solar at www.energizersolar.com
Fault Description
Charge soft start fault
MOSFET UTP fault
always on
Anderson hardware OCP fault
Anderson software OCP fault
PV hardware OCP fault
PV1 software OCP fault
PV2 software OCP fault
Car charge output OCP fault
PV output OVP
(over voltage protection) fault
PV1 input OVP fault
PV2 input OVP fault
Anderson OTP fault
always on
PV1 OTP fault
always on
PV2 OTP fault
always on
Car charge output OTP fault
always on
Abnormal communication
Abnormal USB
code always on
Abnormal type C
code always on
Battery voltage is too low,
The battery is broken
Auto recover after fault is cleared
Turn on and off, contact after sales if still not fixed.
Remove PV charge, auto recover after connecting PV and turn on.
Turn off output, manual recover after fault is cleared.
Remove PV charge, auto recover after connecting PV and turn on.
Stop PV1 charging, auto recover after connecting PV and turn on.
Stop PV2 charging, auto recover after connecting PV and turn on.
Turn off output, manual recover after fault is cleared.
Stop PV. Auto recover after fault is cleared.
Stop PV1. Auto recover after fault is cleared.
Stop PV2. Auto recover after fault is cleared.
Turn off output, manual recover after fault is cleared.
Stop PV1. Auto recover after fault is cleared.
Stop PV2. Auto recover after fault is cleared.
Turn off output, manual recover after fault is cleared
Turn off and on, or change operation environment. Contact after
sales support if still not fixed.
Auto recover after removing abnormal USB.
Auto recover after removing abnormal type C.
16
Solution
Contact after sales support.
ENGLISH

Publicidad

loading