ENGLISH
FIG. 1
1
2
6
7
8
5
9
4
3
1.
Test Remote #1 (Red)
2.
F-Connector
3.
Battery Cap
4.
2x AAA Batteries (included)
5.
TEST Button
6.
PASS LEDs
7.
OPEN Fault LED
8.
SHORT Fault LED
9.
Pocket Clip (Back)
NOTE: There are no
user-serviceable parts
inside tester.
VDV512-100 Instructions
GENERAL SPECIFICATIONS
The Klein Tools Coax Explorer
2 verifies proper continuity of F-connector coaxial cables and
®
maps their location. Color-coded push-on remotes allow for up to four cables to be tested
and mapped, displaying cable status via LED indicators (PASS, OPEN, or SHORT) that also
identify the cable/remote location. Remote #1 (red) is included, additional remotes are available
separately.
• Environment: Indoor
• Operating Altitude: 10000 ft. (3000 m) maximum
• Operating Temperature: 32° to 122°F (0° to 50°C)
• Storage Temp: -4° to 140°F (-20° to 60°C)
• Relative Humidity: 10% to 90% non-condensing
• Dimensions (including remote holder): 5.7" x 2.3" x 1.1" (145 x 32 x 29 mm)
• Weight (including batteries): 4.8 oz. (136 g)
Specifications subject to change.
TESTING/MAPPING CABLES
NOTE: Not for use on powered circuits or outlets.
1
1. Connect test remote
to one end of the cable or outlet to be tested. If necessary, use
an F-adapter (not included) to connect the test remote to the cable.
2. Connect the opposite end of the cable or outlet to be tested to the F-connector
the Coax Explorer
2.
®
5
3. Press and hold the TEST button
6
LED
will light. If there is a problem with the cable, one of the FAULT LEDs (OPEN
8
or SHORT
) will light.
TESTING AN UNINSTALLED CABLE
1. Using an F-adapter (not included), connect a test remote
be tested.
2. Connect the opposite end of the cable to be tested to the F-connector
Explorer
2.
®
5
3. Press and hold the TEST button
6
PASS LED
will light. If there is a problem with the cable, one of the FAULT LEDs
7
8
(OPEN
or SHORT
) will light.
BATTERY REPLACEMENT (FIG. 1)
When the TEST button is pressed and no LEDs light, the batteries must be replaced.
3
1. Unscrew the battery cap
.
2. Remove and recycle the two spent AAA batteries
3. Install two new AAA batteries, with the positive (+) side facing into the tester as shown.
4. Screw battery cap tightly back into place.
Remove the batteries when the tester is not in use for a prolonged period of time. Do not expose
to high temperatures or humidity. After a period of storage in extreme conditions exceeding the
limits mentioned in the GENERAL SPECIFICATIONS section, allow the tester to return to normal
operating conditions before using.
FCC AND IC COMPLIANCE
See this product's page at www.kleintools.com for FCC compliance information.
Canada ICES-003 (B) / NMB-003 (B)
WARRANTY
www.kleintools.com/warranty
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items must be properly
disposed of in accordance with local regulations. Please see
www.epa.gov/recycle for additional information.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street, Lincolnshire, IL 60069
1-800-553-4676
customerservice@kleintools.com
www.kleintools.com
. If the cable is wired correctly, the top (red) PASS
1
to one end of the cable to
2
on the Coax
. If the cable is wired correctly, the corresponding
4
.
STORAGE
BASED ON 1330429 Rev. 11/21 E
2
on
7