Descargar Imprimir esta página

Calorex LEVITTAS 45 L G2 Instructivo De Instalación, Operación Y Mantenimiento página 27

Calentador de depósito eléctrico

Publicidad

Idiomas disponibles

Idiomas disponibles

27 / EN
To activate the function, press the "ECO" button, which will light up.
In this mode, the temperature can still be selected manually, but adjusting its value will deactivate the
ECO function. This function can be deactivated by pressing the "ECO" buttom, which will turn o . To
reactivate it, press the "ECO" button again. Whenever the "ECO" function or the product itself is
switched o and then on again, the function will keep learning the consumption levels.
To voluntarily delete the acquired data, press and hold the "ECO" button for more than 3 seconds.
Once the reset process has been completed, the "ECO" button will flash quickly to confirm the
deletion of the data is complete, the word "ECO" blinks rapidly to confirm the e ective cancellation
of data.
Shower Ready display
The product is equipped with an intelligent function to minimize the water heating time.
No matter what temperature the user selects, the "Shower Ready" icon will light up as soon as
there is su cient water for at least one shower (40 liters of hot water mixed at 40 ºC).
Diagnostic
Whenever one of the following faults occurs, the appliance enters the "fault mode" and the LED
indicator (Fig. 8a/b Ref.1) will be lit and flashing in red.
Error table
The type of malfunction is indicated on the display, wich will show "Er" flashing, alternating
with the relevant error code, according to the following table:
Code
Description
01
Internal malfunction of the circuit board.
61/62
Internal malfunction of the circuit board (NFC communication or NFC data).
10
Broken temperature probes ( open or short circuited) - boiler outlet.
11
Excessive water temperature detected by single sensor - boiler outlet.
12
General excessive water temperature (circuit board fault) - boiler outlet.
14
Failure to heat water with powered heating element - boiler outlet.
15
Overheating caused by lack of water - boiler outlet.
20
Broken temperature probes (open or short circuited) - boiler inlet.
21
Excessive water temperature detected by single sensor - boiler inlet.
22
General excessive water temperature (circuit board fault) - boiler inlet.
24
Failure to heat water with powered heating element - boiler inlet.
25
Overheating caused by lack of water - boiler inlet.
Reset
To reset an error, when possible, switching o and on from the ON/OFF " " knob.
If the cause of the malfunction disappears immediately after resetting, the appliance resumes
normal operation. If, on the other hand, the error code continues to appear on the display,
contact the Calorex Service center.

Publicidad

loading

Este manual también es adecuado para:

Levittas 65 l g2