Descargar Imprimir esta página

AUX CL80001 Manual De Instalación Y Usuario página 61

Publicidad

Idiomas disponibles

Idiomas disponibles

14 .Anti-F
*
The Anti-F functions when the unit is turned off with the remote
controller in COOL, DRY or AUTO mode. It will operate in HEAT
mode (FAN mode for cool only units), with the internal fan
running with weak flow for 3 minute before stop, to remove the
moisture within the evaporator so as to prevent it from giving
off bad smell from mold.
*
This function is not set in the factory. You may set it or cancel it
any time you want as follows: With both the unit and the remote
controller OFF, point the remote controller at the unit and press
"Anti-F" button once, the buzzer will sound 5 times after 5 times,
indicating this function is set. Once set, this function will remain
valid except when the unit is power off or until it is canceled.
*
To cancel Anti-F:
1. Power off the unit.
2. With both the unit and the remote controller OFF, point the
remote controller at the unit and press this button once, the
buzzer will sound 3 times after 5 times, indicating this function
is canceled.
Note:
*
With Anti-F activated, it is advised not to turn ON the unit
again before it is fully OFF.
*
Anti-F function will be invalid when OFF timer is set.
15.
This button has no function.
REMOTE CONTROLLER
61

Publicidad

loading

Este manual también es adecuado para:

Cl80004