OPERATING AND MAINTENANCE MANUAL
SWITCHMATIC SERIES CONTROLLER
- ART function (Automatic Reset Test). When the device is disconnected due to
the intervention of the protection system due to lack of water, the ART tries, with a
programmed periodicity, to connect the device until the water supply is restored. See 'ART:
Automatic reset function'. It must be activated in step 6 of the ADVANCED MENU (Ar1).
- Rapid cycle warning: when the hydro-pneumatic tank has lost too much air and, as a
result, frequent starts and stops occur, this warning is activated. Activated (rc2).
- Manual reset button (RESET).
- 3 operating modes: differential, reverse and synchronised (SW2 only).
- Control panel and 3-digit numerical display, LED indicators and pushbuttons.
- Free potential contact for monitoring of alarms displayed on the screen caused by
irregularities or problems in the system.
(only SWITCHMATIC 2A/3A).
- Possibility of configuration:
- Stand-by mode.
- Minimum fast cycle time.
- Switch-on and switch-off delay.
5. TECHNICAL CHARACTERISTICS
• Rated pump power
• Power supply
• Electrical output
• Maximum pressure
• Frequency
• Maximum current
• Degree of protection
• Maximum water temperature
• Maximum ambient temperature
• Start-up pressure
• Range of unemployment
• Maximum differential (Pstop-Pstart)
• Minimum differential (Pstop-Pstart)
• Factory setting (start/stop)
• Hydraulic network connection
• Net weight (without cables)
www.proindecsa.com / proindecsa@proindecsa.com
0,37-2,2KW (SW1-SW2)
~1 x 110-230 Vac (SW1-SW2)
~1 x 48-230 Vac/Vdc (SW3)
Contacto libre de potencial (SW3)
0,8 MPa (+ version = 1,2MPa)
50/60Hz
16A, cos fi ≥ 0.6
IP55
50ºC
60ºC
0,5÷7 bar (+ version = 11 bar)
1÷8 bar (+ version = 12 bar)
7,5 bar (+ version = 11,5 bar)
SW: 0,5 bar
SW2 en sincronización: 1 bar
3/4 bar
G 1/4" Hembra - NPT 1/4"
0,3 kg
14