Legend Figure 1
1.
Mains connection cable (black)
2. Control box
3. Mains supply cable (blue)
4. Pressure line connection with integrated non-return valve
5. Rope lugs
6. Pump housing
7.
Pump base
8. ON/OFF Switch
9.
Red Alarm Light
Assemble pressure line
The device has a non-return valve at the pressure line outlet. This prevents the pressure
line from emptying every time the device comes to a standstill.
The device is installed either:
• Stationary with fixed piping (see fig. 2 next page) or stationary with flexible hose line.
• Fit the pressure line to the pressure line connection (4), p.10.
• Secure the mains supply cable (3) to the pressure line with cable ties.
• Before immersing the device in wells and shafts, attach a suitable rope to the rope
lugs (5).
Clarify possible special conditions for the installation before operating the
pump! If, for example, a power failure, contamination or a defective seal can
lead to property damage, additional protective measures must be installed.
These protective measures are, for example: pumps running in parallel on a separate-
ly fused circuit, moisture sensors for shutdown, and similar safety devices. If in doubt,
be sure to seek advice from a sanitary specialist.