TOOL ELEMENTS
Coilnailer
MAINTENANCE
Warning
y
Repairs other than those described here should be
performed only by trained, qualified personnel. Contact
SENCO for information at:
+31 320 295 575.
y
Read section titled "Safety Warnings" before maintaining
tool.
y
Only use spare parts specified by manufacturer or autho-
rized representative.
_______________________________________________
y
All screws should be kept tight. Loose screws result in
unsafe operation and parts breakage.
y
Check monthly
_______________________________________________
y
With tool disconnected, make daily inspection to assure
free movement of workpiece contact and trigger. Do not
use tool if workpiece contact or trigger sticks or binds.
_______________________________________________
y
Squirt Senco pneumatic oil (5 to 10 drops) into the air
inlet twice daily (depending on frequency of tool use).
Other oils may damage O-rings and other tool parts.
y
Some Senco tools are Oil Free and DO NOT require oil,
Check label.
_______________________________________________
y
Wipe tool clean daily and inspect for wear. Use non-
flammable cleaning solutions only if necessary.
y
Do Not Soak.
y
Caution: Such solutions may damage O–rings and other
tool parts.
y
Dispose of cleaning materials properly.
CN2
CN1
CN5
CN1
Workpiece Contact
CN2
Exhaust
CN3
Trigger
CN4
Inlet
CN5
Magazine latch
CN6
Magazine Cover
8
CN4
CN3
CN6
TROUBLE SHOOTING
SYMPTOM
Air leak near top of tool. / Sluggish operation
1
SOLUTION
Verify air supply / tighten screws or install Repair
Kit – See Parts Manual
SYMPTOM
Air leak near bottom of tool / Poor return.
2
SOLUTION
Clean tool / tighten screws or install Repair Kit
See Parts Manual
SYMPTOM
Other problems.
3
SOLUTION
Contact SENCO.
Should Staple Jam Occur:
Disconnect Air Supply
Remove Fasteners
Clear the Jam
Follow loading Procedure

Publicidad