Movements made during the learning with 2 motors:
Ÿ Motor 2 closes until running into the limit switch or until receiving a START impulse.
Ÿ Motor 1 closes until running into the limit switch or until receiving a START impulse.
Ÿ Pause of 1 second.
Ÿ Motor 1 opens until running into the limit switch or until receiving a START impulse.
Ÿ Motor 2 opens until running into the limit switch or until receiving a START impulse.
Ÿ Pause of 1 second.
Ÿ Motor 2 closes until running into the limit switch or until receiving a START impulse.
Ÿ Motor 1 closes until running into the limit switch or until receiving a START impulse.
Ÿ Pause of 1 second.
Ÿ Motor 1 opens, the first START command causes the beginning of the decelerated motion, the following
START command or the opening limit switch causes the end of motor 1 motion in opening.
Ÿ Motor 2 opens, the first START command causes the beginning of the decelerated motion, the following
START command or the opening limit switch causes the end of motor 2 motion in opening.
Ÿ Pause of 1 second.
Ÿ Motor 2 closes, the first START command causes the beginning of the decelerated motion, the following
START command or the closing limit switch causes the end of motor 2 motion in closing.
Ÿ Pause of 1 second.
Ÿ Motor 2 closes, the first START command causes the beginning of the decelerated motion, the following
START command or the closing limit switch causes the end of motor 2 motion in closing.
Ÿ End of learning, the LED L9 and the flashing light signal that the learning has been completed and turn off.
Movements made during the learning with 1 motor:
Ÿ Motor 1 closes until running into the limit switch or until receiving a START impulse.
Ÿ Pause of 1 second.
Ÿ Motor 1 opens until running into the limit switch or until receiving a START impulse.
Ÿ Motor 1 closes until running into the limit switch or until receiving a START impulse.
Ÿ Motor 1 opens, the first START command causes the beginning of the decelerated motion, the following
START command or the opening limit switch causes the end of the motion of motor 1 in opening.
Ÿ Pause of 1 second.
Ÿ Motor 1 closes, the first START command causes the beginning of the decelerated motion, the following
START command or the closing limit switch causes the end of the motion of motor 1 in closing.
Ÿ End of learning, the LED L9 and the flashing light signal that the learning has been completed and turn off.
In the event of the learning procedure not work then check the signaling of LED L9.