14 - SOFT START
This function adds 1s at reduced speed at the beginning of each movement. It is particularly recommended for
the electromechanical operators.
Write down DIP1_1 position.
Ÿ
Cut power to the control unit.
Ÿ
Press and hold MEMO button.
Ÿ
Supply the control unit.
Ÿ
Release MEMO button.
Ÿ
The blue led L9 starts to flash at regular intervals:
Ÿ
- short flashings, inactive function
- longer flashings, active function.
· The flashing light will light up steadily
Ÿ
Bring DIP1_1 in ON to activate the function or in OFF to deactivate it.
Ÿ
Press and hold MEMO button.
Ÿ
After a few seconds, the led L9 will turn off and the flashing light will make two short flashings to confirm the
Ÿ
correct storage.
Bring DIP1_1 back to its original position.
Ÿ
14 - FINAL CHECKS
• Make some opening and closing cycles to check the right operation of the automation and adjust the doors
force, acting on FORCE trimmer. If you have to make large adjustments from the values used during the learning
sequence then it may be necessary to repeat the learning procedure.
• Check the right operation of the automation.
16 - SUMMARY OF FLASHING LIGHT SIGNALLING
Edge detection before motion
Photocell break/interruption at rest in presence of
a START command ( DIP1_1 = ON )
LEARNING OK
LEARNING FAILED
Device
Opening
Closing
Signalling
3 slow flashes
5 fast flashes
0,8s ON, 0,8s OFF
0,4s ON, 0,4s OFF
3s ON, 1s OFF
Repeated 3 times
0,3s ON, 0,3s OFF
Repeated 4 times
F4
Effect
Gate/door locked
When released, it opens
The gate is opening
The gate is closing
Learning correctly made
Learning failed