Finish Mounting
❒
Align the cover plate, gasket, and the mounting
bracket hole. Secure with M5 x 0.8 x 40 mm
mounting screw supplied.
❒
Push the rubber plug firmly into place.
❒
If not installed on a weatherproof box, caulk
between the cover plate and mounting sur-
face with silicone weather sealant.
❒
Adjust the lamp holders by loosening the
thumb screws but do not rotate the lamp hold-
ers more than 180° from the factory setting.
When screwing in the floodlamps, do not
overtighten.
To avoid water damage and
electrical shock, keep lamp
holders aimed below horizontal.
All manuals and user guides at all-guides.com
Rubber Plug
Specifications
Range . . . . . . . . . . . . . . . 70 feet (21.0 m); 100 feet
Sensing Angle . . . . . . . . . Up to 270° (Adjustable)
Fixture Load . . . . . . . . . . Up to 300 Watts Maximum
Sensor Load Capacity . . . Up to 1000 Watts (8.3 amps)
Power Requirements . . . . 120 VAC, 60 Hz
Operating Modes . . . . . . . TEST, A UTO, a nd M ANUAL
Time Delay . . . . . . . . . . . 1, 5, 20 minutes
HeathCo LLC reserves the right to discontinue
products and to change specifications at any time
without incurring any obligation to incorporate new
features in products previously sold.
-8-
(30.5 m) with Range Boost.
Varies with surrounding
temperature.
Tungsten Incandescent [Up
to 150 Watts maximum each
lamp holder.]
Maximum Tungsten Incan-
descent
OVERRIDE
598-1290-02