Descargar Imprimir esta página

BGS technic 3141 Manual De Instrucciones página 6

Publicidad

Idiomas disponibles

Idiomas disponibles

GREASING A GREASE FITTING / GREASE NIPPLE
The grease coupler provided at the end of the grease gun extension has a jaw type construction.
The coupler jaws will snap on to a grease fitting and maintain a tight fit.
When connecting the coupler to the grease fitting, press the coupler straight onto
the grease fitting to form a snug fit.
Start operating the grease gun with the coupler as square to the grease fitting as
possible.
Once greasing is completed, slightly tilt the coupler, twist and pull back.
The tilt and twist action will allow easy removal of the coupler from the grease fitting.
Warning
Never try to dis-engage the coupler by pulling it out straight.
TROUBLESHOOTING
Problem
Grease gun pumps little or no
grease.
Excessive grease leaks out
from the back side of the
grease gun - around the
plunger rod.
Grease leaks from the
connection between the grease
gun head & the extension /
extension & coupler
Grease leaks from the coupler
body joint or from in-between
the coupler jaws & grease
nipple.
MAINTENANCE AND CLEANING
Do not clean the grease gun with aggressive detergents or aggressive chemicals.
The grease gun is low maintenance unit in general. Because of the operator obligations have to be
regularly checked parts like head unit, screw joints, lever, hoses, nozzle, etc to avoid environmental or
property damage and to avoid persons being hurt.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Cause
Trapped air pockets in grease Prime grease gun
Thick grease or frozen
grease
Blocked grease gun
extension
Blocked grease gun head
Damaged grease gun rubber
follower
Loose connection
Damaged grease coupler
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
Remedy
Use a lower viscosity grease /
heat the grease gun barrel to
unfreeze the grease.
Remove grease gun extension. if
grease gun pumps grease without
the extension, then the problem is
with the extension, which should
be cleaned / replaced
Disassemble the grease gun
head to check for any
contaminants blocking the
passage of grease. Clean & re-
assemble the grease gun head.
Change follower
Tighten the connection using
teflon or any other thread sealant
Change coupler
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed

Publicidad

loading