DRAINING THE TANK
See Figure 11.
To help prevent tank corrosion and keep moisture out of
the air used, the tank of the compressor should be drained
daily.
To drain:
Verify that the compressor is turned off.
Holding the handle, tilt the compressor toward the drain
valve so that it's set in a lower position.
Open the drain valve by rotating it ¼ turn
counterclockwise.
Keep the compressor tilted until all moisture has been
removed.
Drain moisture from tank into a suitable container.
NOTE: Condensate is a polluting material and should
be disposed of in compliance with local regulations.
If drain valve is clogged, release all air pressure by
pulling the safety valve. Remove and clean valve, then
reinstall.
WARNING:
Unplug the air compressor and release all air from
the tank before servicing. Failure to depressurize tank
before attempting to remove valve may cause serious
personal injury.
Close the drain valve by rotating it ¼ turn clockwise.
CHECKING THE SAFETY VALVE
See Figure 12.
WARNING:
Do not attempt to tamper with safety valve. Anything
loosened from this device could fly up and hit you.
Failure to heed this warning could result in death or
serious personal injury.
The safety valve will automatically release air if the air
receiver pressure exceeds the preset maximum. The valve
should be checked before each day of use by pulling the
ring by hand.
Turn the air compressor on and allow the tank to
fill. The compressor will shut off when the pressure
reaches the preset maximum.
Turn the air compressor off.
Pull the ring on the safety valve to release air for three
to five seconds.
Release the ring. Air must immediately stop escaping
when the ring is released. Any continued loss of air
after releasing the safety valve ring indicates a problem
with the safety valve. Discontinue use and seek service
before continued use of the air compressor.
OPERATION
DRAIN VALVE (closed)
WARNING:
If air leaks after the ring has been released, or if the
valve is stuck and cannot be actuated by the ring,
do not use the air compressor until the safety valve
has been replaced. Use of the air compressor in this
condition could result in serious personal injury.
END OF OPERATION/STORAGE
Turn the ON/OFF switch to the OFF (O) position.
Unplug power cord from wall outlet and wrap around
handle area to prevent damage when not in use.
Wearing safety glasses, drain tank of air by pulling the
ring on the safety valve. Use other hand to deflect fast
moving air from being directed toward your face.
Drain tank of condensation by opening drain valve on
bottom of tank. Tank pressure should be below 10 PSI
when draining tank.
Air hose should be disconnected from compressor and
hung open ends down to allow any moisture to drain.
Compressor and hose should be stored in a cool, dry place.
Compressor can be stored in horizontal and vertical
position.
WARNING:
Always drain the tank before to store compressor in
vertical position.
15
DRAIN VALVE
(open)
Fig. 11
SAFETY
VALVE
Fig. 12