Preparation / Prior to installation / Start-up / Maintenance and cleaning / Disposal
- Pencil / making tool
- 2-pole voltage tester
- Screwdriver
- Electric drill
- Bit (approx. ø 6 mm)
- Side cutting pliers
- Ladder
Prior to installation
Important: The electrical connection must be
established by a qualified electrician or a person
trained to perform electrical installations. This per-
son must be familiar with the properties of the light
and the connection regulations.
Familiarise yourself with all the instructions and
diagrams in this manual, as well as with the light
itself, before you install it.
Before installation ensure that the circuit, to which
the light will be connected, is not energised. To
do so, remove the fuse or switch off the circuit
breaker in the fuse box (0 position).
Use the voltage tester to verify the de-energised
status.
Start-up
Mounting the light
Remove the screws
the connection housing
mounting angle
2
Use the slotted holes in the mounting bracket
intended for the screws to mark the bores.
Now drill the fixing holes (approx. 6 mm, depth
approx. 40 mm). Be careful not to damage the
supply line.
Insert the dowels
1
Fasten the mounting bracket
provided screws
3
Feed both the L and N cables (see Fig.)
through the protective tubes
Now connect the connection cable of the light
to the mains connection cable (external)
using the terminal block
visible at the side of
4
and remove the
5
from the back.
into the bores.
with the
2
.
.
8
7
.
6
Note: Be sure to correctly connect each of the
individual wires of the mains connection cable
(external): black or brown live wire = L symbol,
blue neutral wire = N symbol. Connect the pro-
tective conductor (green-yellow) to the marked
ground terminal
housing
.
5
Now use the screws
the mounting bracket
Replace the fuse or switch on the circuit breaker
(I setting) inside the fuse box.
Your light is now ready to use.
Maintenance and cleaning
Disconnect the light from the mains circuit before
cleaning. To do so, remove the fuse or switch off
the circuit breaker in the fuse box (0 position).
For electrical safety, never clean the light with
water or other liquids, or immerse it in water.
CAUTION! DANGER OF BURNS DUE
TO HOT SURFACES!
Allow the light to cool completely.
Do not use solvents, benzene or similar
substances. They could damage the light.
Only use a dry, lint-free cloth for cleaning.
Replace the fuse or switch on the circuit breaker
(I setting) inside the fuse box.
Disposal
2
The packaging is made entirely of recyclable mate-
rials, which you may dispose of at local recycling
facilities.
Observe the marking of the packaging
materials for waste separation, which
b
a
are marked with abbreviations (a) and
numbers (b) with following meaning:
1–7: plastics / 20–22: paper and fibre-
board / 80–98: composite materials.
inside the connection
to screw the light to
4
.
2
RISK OF ELECTRIC SHOCK!
RISK OF ELECTRIC SHOCK!
GB/IE