15. ALARMS
MESSAGE
TRANSDUCER FAILURE
TANK OVERFILLED
AUTOMATIC STOP
MANUAL STOP
OVERCURRENT
46
CAUSE
The pressure transducer
is missing, damaged, or
not wired correctly.
Input 4 has been
activated.
Input 1 has been
activated.
The STOP/AUTO
button was pressed
The pump is consuming
above the nominal
consumption.
SOLUTION
Check that the transducer is
connected with the correct polarity
to the specific input for the pressure
transducer. If the error message
persists, it may mean that the
transducer is defective and must be
replaced.
In a dirty water lifting system, it
indicates that the level float in charge
of indicating the over-level of the
tank is active, therefore there is a
danger of overflow.
In a tank-fill booster system, it
indicates that the target tank is about
to overflow.
This message will only be displayed
in a BOOSTER SET or BOREHOLE
PUMP type of application, and
indicates that the pump water supply
tank is empty.
The intervention of the installer has
blocked the device, therefore the
pumps are stopped and disabled for
their automatic operation. Press the
STOP/AUTO button to re-enable the
automatic operation of the device.
Check the nominal consumption of
the affected motor indicated in menu
4. MOTOR CONSUMPTION.
If the value entered at this point is
correct, it may indicate an internal
motor problem that causes this
excess consumption.
Also check that the voltage received
by the motor while running is correct
and that there is no attenuation
in the input voltage, which would
directly imply excess motor
consumption.