Poor ice-making
result
Water pump does
not work or
produces noise.
Refrigerating system leaks
Refrigerating system blocks
1.Poor heat dissipation.
2.The water temperature is too
high.
3.The ambient temperature is too
high.
1. Water pump is damaged.
2. The appliance has not been
cleaned for a long time, which
has resulted in the formation of
mucoid substance at the water
inlet of the water pump, so that
the
water-pumping
smooth. There is air in the
water pipe, so there will be
resonance
noise
when pumping water.
English - 11 -
Call customer service
Call customer service
1. Leave an 8-inch (20cm) clearance
on all sides of the ice maker for
proper ventilation.
2. Fill the water reservoir with water
ranges between 8℃ and 28℃.
3. Operate the ice maker at an
environment with an ambient
temperature between 10℃ and
32℃.
1. Contact
department for replacing the
water pump.
2. The appliance should be cleaned
in one to two weeks, and some
neutral cleaning agents (such as
is
not
detergent and soapy water etc.)
can be added if necessary.
produced
the
after-sales