Descargar Imprimir esta página

Euramco RAMFAN EX50LI-40VDC MAKITA Manual Del Operador página 3

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
Specifications
Power
700W (0.9hp) @ 115V
Amps
Run: 6.7A @ 115V
Run: 3.8A @ 230V
Weight
50.0lbs / 23.0kg (no wheels or batteries)
54.0lbs / 25.0kg (with wheel kit, no batt.)
Dimensions
Inches:
(H x W x D)
22.0 x 21.0 x 13.0 (no wheels)
23.0 x 21.0 x 16.5 (with wheels, handle)
Centimeters:
56.0 x 53.4 x 33.0 (no wheels)
58.0 x 53.4 x 42.0 (with wheels, handle)
Airflow
10,352 cfm / 17,588 m
(AMCA certified)
Operating
Fan:
Temp.
-20°F – 120°F / -30°C – 50°C
Range
Batteries:
Follow manufacturer's guidelines
Runtime
48 min (2 x 8.0 Ah batteries)
Noise
87 dBA
@3m (10ft)
In the box
EX50Li-40V
blower equipped with two Makita
DC
BATTERY HOLDERS.
Wheeled dolly w/extendable handle, pre-mounted
AC cord suitable for country of operation
Carry strap
Batteries
BATTERIES NOT INCLUDED.
Use Makita 40V max XGT® 8.0 Ah batteries with the fan.
The fan will operate when using one or two batteries.
Check battery fuel gauge. A full battery is ideal.
Insert batteries into holders until seated.
Connect the battery cable to each battery in use.
Only one battery is needed for the fan to operate,
both batteries will provide the best performance
during operation.
Removing both batteries will turn off the controller.
Fan will stop running when the voltage of the
batteries in use reaches 27 V
Charge batteries using only the genuine Makita
battery charger
— 230V
50/60 Hz
AC
AC
| Start: 13.0A
AC
| Start: 8.0A
AC
3
/hr
.
DC
Operating Instructions
Prior to Start
Position blower in operating position, pointing horizontally,
up or down. If horizontal (normal) adjust tilt to point
towards center of opening. Distance from opening should
be 8-14 feet for best airflow.
If used with ducting, fully extend duct and place into the
area or opening as required. For High Expansion foam
operation see separate Operating Manual.
Make sure the blower is in a stable position on its vibration
pad feet.
Once blower is started, the Rollover Protection System
(ROPS or 'knockdown' protection) activates: If moved from
the start position by more than 45° from vertical the fan will
stop, red FAULT LED will flash for some seconds and reset
to ready green. Reposition and restart.
Figure 1: Diagram of EX50Li-40V Makita control panel
Battery Operation
Refer to Figure 1 above for the following instructions. With
both batteries installed, PUSH and HOLD left knob to wake
controller. Status LED on right side of control panel will be
WHITE, battery LEDs indicate combined charge level.
Start fan by turning RIGHT knob CW until desired speed, 11
clicks to full, OR PUSH and HOLD RIGHT knob and fan
advances to MAX speed, Status LED flashes WHITE. Turn
knob to adjust.
PUSH and HOLD LEFT knob to STOP fan. Restart as above.
Rotating the LEFT knob CW direction will control the scene
lights OFF-ON-HIGH-OFF and CCW OFF -HIGH-ON -OFF.
When fan is on but motor hasn't turned for 60 minutes
controller will disconnect and unit will shut down. There is
no off switch. Reducing fan speed will extend runtime on
batteries.
3