STACKING THE WASHER AND DRYER (if desired)
If you are planning to stack the washer and dryer, order Stacking Kit number GEFLSTACK to be used for this dryer .
Kit sold separately .
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT
•
local electrical inspector's use .
IMPORTANT
•
codes and ordinances .
Note to Installer
•
– Be sure to leave these
instructions with the Consumer .
Note to Consumer
•
future reference .
• Service must be performed by a qualified installer .
• Do not allow children on or in the appliance . Close
supervision of children is necessary when the
appliance is used near children .
• Proper installation is the responsibility of the installer .
GE APPLIANCES STACK KIT
Order on-line at GEApplianceparts.com, 24 hours
a day or by phone at 877.959.8688 during normal
business hours .
Part Number
Accessory
GEFLSTACK
Complete Stack Kit
KIT CONTENTS (GE APPLIANCES
KIT # GEFLSTACK)
Left hand bracket
4 #12 x 1" screws
4 #8 x 1/2" screws
TOOLS YOU WILL NEED
Phillips screwdriver
Pliers
Open-ended wrench
49-3000063
Optional Instructions
– Save these instructions for
– Observe all governing
– Keep these instructions for
Right hand bracket
4 rubber pads
Gloves
Level
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
WARNING
Keep flammable materials and vapors, such as
gasoline, away from dryer .
Failure to do so can result in death, explosion, or fire .
• The dryer MUST be vented to the outdoors .
• Minimum clearance between dryer cabinet and
adjacent walls or other surfaces is:
0" either side
1" rear, front and top
• Consideration must be given to provide adequate
clearance for installation and service .
• Closet doors must be louvered or otherwise ventilated
and doors must contain a minimum of 120 square
inches of open area .
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT
THE REAR OF THE DRYER, THE CONFIGURATION
OF THE DUCTING MAY REQUIRE GREATER THAN
1" OF REAR CLEARANCE .
Gas Dryers Only:
• No other fuel burning appliance shall be installed in
the same closet as a gas dryer .
• The dryer must be disconnected from the gas
supply piping during pressure testing at pressures
greater than ½ psi (3 .5 kPa) .
• A 1/8 inch NPT minimum plugged tapping,
accessible for test gauge connection, must be
installed immediately upstream of the gas supply
connection to the dryer .
MINIMUM CLEARANCE OTHER
THAN ALCOVE OR CLOSET
INSTALLATION
Minimum clearance to combustible surfaces and
for air opening are: 0" both sides, 1" rear and 1" top .
Consideration must be given to provide adequate
clearance for installation and service .
INSTALLATION PREPARATION
Remove the packaging .
Flatten the product carton to use as a pad to lay the dryer
down on its side . Continue using the carton to protect the
finished floor in front of the installation location .
- Explosion Hazard
15