Electrical wiring
There is a danger to life if the wires are incorrectly connected.
Connection to a suitable power supply should only be carried out by a qualified and
competent electrical engineer.
Warning: The fixed wiring of the power cord connection must be equipped with a
disconnect device (leakage protection switch) with a contact distance greater than 30mm
according to the wiring rules.
Connect the unit in accordance with the applicable regulations of your country, federal state, city or local
authority.
Connect the unit to a standard energy supply network.
For a proper electrical connection, adjust the power ratings to the local circumstances and requirements.
Equipotential bonding terminal in electrical appliances is to connect exposed metal and conductive
parts of electrical devices and other devices in electrical appliances with artificial or natural grounding
conductors to reduce potential differences (reduce and prevent the risk of electric shock).
This appliance is supplied unplugged and require hardwiring to a suitable electrical power supply.
CU470 requires a 3kW 230V mono-phase circuit at 50Hz.
Connect the wires correctly according to their colour coding. This appliance is wired as follows:
Wire colour
Yellow/green
Blue
Brown/grey or black
The appliance must be earthed. If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
Electrical wiring (for CU470-E only)
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
CU470_ML_A5_v2_20240202.indb 5
CU470_ML_A5_v2_20240202.indb 5
DANGER of electric shock from incorrect connection
Wire function
Earth wire, protective conductor
Neutral wire, neutral conductor
Live wires, Phase L1
To terminals of power supply
Terminal marked E
Terminal marked N
Terminal marked L1
EN
5
2024/2/2 14:12
2024/2/2 14:12

Publicidad

loading

Este manual también es adecuado para:

600 cu470600 cu470-e