Diode
Test
Continuity
Check
Battery
Test current
Input
Impedance
ACV Bandwidth
DCA voltage
drop
Display
Overrange
indication
Polarity
Measurement
Rate
Low Battery
Indication
Battery
Fuses
Operating
Temperature
Storage
Temperature
Operating
Humidity
Storage
Humidity
Operating
Altitude
Weight
Size
Safety
Test current
of 1 mA maximum,
open circuit
voltage
2.8V DC typical
Audible
signal
will sound
if the resistance
is
less than approximately
30£2
9V (6mA);
1.5V (100mA)
>IM_
45Hz to 450Hz
200mV
3 ½ digit, 2000 count
LCD, 0.5" digits
"1" is displayed
Automatic
(no indication
for positive
polarity);
Minus (-) sign for negative
polarity.
2 times
per second,
nominal
"BAT"
is displayed
if battery
voltage
drops
below
operating
voltage
one 9 volt (NEDA
1604) battery
mA, pA ranges;
0.2A/250V
fast blow
A range;
10A/250V
fast blow
41°F to 104°F (5°C to 40°C)
-4°F to 140°F (-20°C to 60°C)
Max 80% up to 87°F (31°C) decreasing
linearly
to 50% at 104°F (40°C)
<80%
7000ft.
(2000)
meters
maximum.
9.17 oz. (260g).
4.78" x 2.38" x 1.57" (121.5mm
x 60.6mm
x
40mm)
For indoor
use and in accordance
with
Overvoltage
Category
II, Pollution
Degree
2.
Category
II includes
local level, appliance,
portable
equipment,
etc., with transient
overvoltages
less than Overvoltage
Category
Ill.