Maintenance & Care
Brush roll reset:
If larger debris becomes lodged in the foot of
the unit and the brush roll shuts off, turn the unit
off and remove the obstruction. Wait approxi-
mately 15 seconds for the motor to cool down
before turning back on. Brush will function again
after allowing time to cool down.
Disposal of batteries
If your Bolt 2-in-1 Cordless Vacuum is to be
disposed of, the batteries should be removed
and disposed of properly.
1. IMPORTANT: Unplug Charger.
2. Remove hand vac from unit and remove
dirt cup from handle.
3. Remove (2) Phillips head screws and
remove the lens from the hand vacuum.
4. Remove (2) Phillips head screws from
the hand vacuum cover.
5. Lift off the hand vacuum cover.
6. Take out push rod.
7. Remove (5) Phillips head screws from the
side of the hand vacuum.
8. Remove the entire battery assembly from
the cover.
9. Cut wires from the PCB and wrap the wire
ends with insulation tape.
10. Keep Battery Pack together – DO NOT
separate individual batteries. For specific
disposal instructions of batteries, please
contact RBRC (Rechargeable Battery
Recycling Corporation) 1-800-822-8837 or
visit www.rbrc.com.
11. Discard remainder of product
CAUTION: Disconnecting the battery
will destroy the appliance and invalidate
the warranty.
www.BISSELL.com
8
WARNING
To reduce the risk of electric shock, turn power switch off
and disconnect polarized plug from electrical outlet before
performing maintenance or troubleshooting checks.
7.
5 screws
WARNING
This product contains Nickel Metal Hydride (NiMH)
rechargeable batteries. According to Federal and State
regulations, removal and proper disposal of NiMH
batteries is required. For removal of
the batteries in your Bolt see
instructions on this page.