Descargar Imprimir esta página

Broan NuTone XN110HL Manual De Instrucciones página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 10
Retrofit Installation
11
Install Knockout Plate, Connect Wires and Install Wiring Panel
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
• Do not use a dimmer switch to operate the light.
2
Screw from
Parts Bag
Fan
• See OPERATION section on page 12 for
details.
• SENSOR/CONTROL switch allows humidity
control to be turned on for automatic
operation and off for fan cleaning and
maintenance purposes.
• Toggle mode can be used to manually turn
fan on.
• SENSOR/CONTROL switch may be located
where it is not easily accessed for everyday
usage; it may need to be labeled and located
where it can't be turned on without being
seen from fan to comply with local and
national codes.
Attach cable
1
clamps to
Knockout Plate.
Knockout Plate
mounts to inside of
Housing and may
be oriented
as desired.
3
Connect wires
120 VAC
Light
LINE IN
CONTROL
Screw set
aside in
Step 6
5
GRD
WHT
BLK
STANDARD OR
MULTI-FUNCTION
WALL SWITCHES
SENSOR /
LIGHT
CONTROL
BLACK
WHITE
ORANGE
SENSOR /
NIGHT
LIGHT
LIGHT
STANDARD OR
MULTI-FUNCTION
WALL CONTROLS
(purchase separately)
XN110HL Installation Guide
4
GRD
WHT
BLK
RED
14/3
NIGHT
LIGHT
14/2
BLK
WHT
RED
GROUND
(green or bare)
BLUE
LIGHT RECEPTACLE WIRES
BROWN
SWITCH
BOX
KNOCKOUT
PLATE
120 VAC
LINE IN
6
WHT
BLU
LIGHT
RED
NIGHT
LIGHT
RED
FAN
BLK
ORG
SENSOR/
CONTROL
BRN
WHT
RECEPTACLES
FAN RECEPTACLE
WIRES