Broan LOSONE SELECT L400 Serie Manual Del Usuario

Broan LOSONE SELECT L400 Serie Manual Del Usuario

Ocultar thumbs Ver también para LOSONE SELECT L400 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

LOSONE SELECT
VENTILATORS
Ceiling/Wall Mount
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 3.
®
L400 SERIES • L500 SERIES • L700 SERIES
TABLE OF CONTENTS
This manual is divided into sections as follows:
• "WARRANTY"
• "TYPICAL INSTALLATION"
This section shows a common installation in new and existing,
frame construction.
- Mounting (new construction)
- Mounting (existing construction)
- Wiring
- Ducting (horizontal blower discharge)
• "MOUNTING OPTIONS"
• "WIRING OPTIONS"
-Wiring Plate Position
• "DUCTING OPTIONS"
- Blower Discharge Positions
- Ducting (vertical blower discharge)
• "USE AND CARE"
• "SERVICE PARTS"
WARRANTY
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for a period
of one year from the date of original purchase. THERE ARE NO OTHER WAR-
RANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PUR-
POSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace,
without charge, any product or part which is found to be defective under normal
use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS
AND TUBES. This warranty does not cover (a) normal maintenance and service
or (b) any products or parts which have been subject to misuse, negligence,
accident, improper maintenance or repair (other than by Broan-NuTone-NuTone),
faulty installation or installation contrary to recommended installation instruc-
tions.
The duration of an implied warranty is limited to the one-year period as specified
for the express warranty. Some states do not allow limitation on how long an
implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-
NUTONE-NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EX-
CLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE-NUTONE SHALL
NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFOR-
MANCE. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior warran-
ties.
To qualify for warranty service, you must (a) notify Broan-NuTone-NuTone at the
address stated below or telephone: 1-800-637-1453, (b) give the model number
and part identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence of
the original purchase date.
In the U.S., contact: Broan-NuTone LLC, 926 West State Street, Hartford, WI
U.S.A. 53027 (1-800-637-1453)
In Canada, contact: Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga,
Ontario L5T 1H9 (1-888-882-7626)
®
LOSONE SELECT
Page 1
Page 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan LOSONE SELECT L400 Serie

  • Página 1 POSE. 10. This unit must be grounded. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS CAUTION AND TUBES.
  • Página 2: Typical Installation

    LOSONE SELECT ® L400 SERIES • L500 SERIES • L700 SERIES Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING (New Frame Construction) WIRING BLACK 10” ROUND DUCT Mounting brackets factory-shipped in BLACK TOP / BACK position for ½” OF HOUSING ceiling material. GROUND TO WIRING PLATE WIRING...
  • Página 3: Mounting Options

    ® LOSONE SELECT L400 SERIES • L500 SERIES • L700 SERIES Page 3 MOUNTING OPTIONS DUCTING OPTIONS yyy @@ @@ @@ @@ @@ @@ yy ¼-20 hex nuts secure mounting brackets to housing. Loosen and BLOWER DISCHARGE POSITIONS re-tighten or remove and replace nuts as necessary for desired mounting bracket position.
  • Página 4: Service Parts

    LOSONE SELECT ® L400 SERIES • L500 SERIES • L700 SERIES Page 4 SERVICE PARTS SERVICE PARTS KEY NO. PART NO. DESCRIPTION 97014744 Housing Assembly 97014728 Mounting Bracket (2 req.) 98009449 Duct Connector 97014822 Damper Flap Assembly (2 req.) 99150415 Screw, 8-18 x ¼...
  • Página 5: Para Montaje En Cielo Raso/Pared

    UN PROPOSITO PARTICULAR. cableado eléctrico o instalaciones no visibles. Durante este período de un año, Broan-NuTone reparará o cambiará, a su opción y sin cobro, cualquier producto o pieza que se encuentre defectuosa bajo uso y servicio normal. 6. Ventiladores con conductos siempre deben extraer hacia el ESTA GARANTIA NO SE EXTIENDE A ARRANCADORES DE LAMPARAS FLUORESCENTES exterior.
  • Página 6: Instalación Típica

    LOSONE SELECT LOSONE SELECT ® ® L400 SERIES • L500 SERIES • L700 SERIES SERIE L400 • SERIE L500 • SERIE L700 Página Page 6 INSTALACIÓN TÍPICA INSTALACIÓN TÍPICA MONTAJE ( Estructura nueva ) CONEXIÓN ELÉCTRICA 4½” X 18½” TO 10” NEGRO Abrazaderas de montaje, (11,4 X 47 a 25,4 cm)
  • Página 7: Opciones De Montaje

    ® ® LOSONE SELECT LOSONE SELECT L400 SERIES • L500 SERIES • L700 SERIES SERIE L400 • SERIE L500 • SERIE L700 Página Page 7 OPCIONES DE MONTAJE OPCIONES PARA LA COLOCACIÓN DE CONDUCTOS yyy @@ @@ @@ @@ @@ @@ yy Las tuercas hexagonales de ¼...
  • Página 8: Piezas De Servicio

    LOSONE SELECT ® ® LOSONE SELECT L400 SERIES • L500 SERIES • L700 SERIES SERIE L400 • SERIE L500 • SERIE L700 Página Page 8 PIEZAS DE SERVICIO PIEZAS DE SERVICIO CLAVE Nº. PIEZA Nº. DESCRIPCIÓN 97014744 Conjunto del alojamiento 97014728 Abrazaderas de montaje (se req.
  • Página 9 BUT PARTICULIER. 6. La décharge des ventilateurs à conduit par l´évent doit toujours Pendant cette période d’un an, Broan-NuTone, à son choix, réparera ou remplacera, se faire à l´extérieur. gratuitement, tout produit ou pièce qui s’avère défectueux sous utilisation et service normaux.
  • Página 10: Installation Typique

    LOSONE SELECT ® ® LOSONE SELECT L400 SERIES • L500 SERIES • L700 SERIES SÉRIE L400 • SÉRIE L500 • SÉRIE L700 Page 10 INSTALLATION TYPIQUE INSTALLATION TYPIQUE MONTAGE (Construction en cours) CÂBLAGE CONDUIT CIRCULAIRE DE NOIR AU Supports DESSUS / 10 po (25,4 cm) NOIR préassemblés pour...
  • Página 11: Options De Montage

    ® ® LOSONE SELECT LOSONE SELECT L400 SERIES • L500 SERIES • L700 SERIES SÉRIE L400 • SÉRIE L500 • SÉRIE L700 Page 11 OPTIONS D’INSTALLATION DES CONDUITS OPTIONS DE MONTAGE yyy @@ @@ @@ @@ @@ @@ yy POSITIONS DE LA DÉCHARGE DE LA SOUFFLERIE Des écrous à...
  • Página 12: Pièces De Rechange

    LOSONE SELECT ® ® LOSONE SELECT L400 SERIES • L500 SERIES • L700 SERIES SÉRIE L400 • SÉRIE L500 • SÉRIE L700 Page 12 PIÈCES DE RECHANGE PIÈCES DE RECHANGE LÉGENDE N DE RÉF. DESCRIPTION 97014744 Boîtier 97014728 Support (2 oblig.) 98009449 Registre 97014822...

Este manual también es adecuado para:

Losone select l500 serieLosone select l700 serie

Tabla de contenido