3.3 Pre Operation
Before using the Centrifuge Juicer, the parts that will be
in contact with the product that will be processed shall be
washed with water.
Assembly Sequence
01
02
03
04
05
01 - Pusher
02 - Liquid Chamber Lid
03 - Sieve
04 - Liquid Chamber
05 - Motor Support Flange
4. OPERATION
4.1 Starting
Make sure the Sieve is properly fitted in the Central Shaft
and Liquid Chamber Lid is fixed by the Fast Lock.
-Put the plug into the socket.
-To start the equipment, just press the "I" Key (#01 Pic.01).
-To turn the equipment OFF, just press the "0" Key (#02 Pic.
01).
-If the Lid is removed from its operating position with the
machine ON, for safety, the equipment will turn OFF. In case
this happens, place the Lid back to its working place, press
the "0" Key and turn the machine ON pressing the "I" Key.
4
Before using the equipment, always verify the sieve.
If you detect any damage, do not use the equipment and
contact the nearest SKYMSEN technical assistant.
To feed the Centrifuge Juicer, follow the steps bellow:
1.Remove the Stumper from the Feeding Throat located on
the Liquid Chamber Lid;
2.Cut the products to be centrifuged in a way they can be
introduced in the Feeding Throat, mentioned above;
3.Press the ON Key to start the Centrifuge Juicer;
4.Introduce the pieces into the Feeding Throat and, with
the Stumper, press them gradually down;
5.After processing the first load, remove the Stumper and
repeat step 4 as many times as it is necessary until all the
pieces are processed;
6.Pay attention to the volume of juice that it is running by
the Liquid Chamber nib, for the juice not to overflow the
Cup;
7.With some products, it can happen an obstruction of
the waste exit opening if there is a great quantity of the
product to be processed. This can be seen if pieces of the
fruit are going out with the juice or when waste stops
falling into the bowl collector or by the Outlet pipe;
8.In this case, turn the machine OFF (even from the
electrical network), loose the Fast Lock and remove the
Liquid Chamber Lid;
9.Remove the waste that is obstructing the exit, wash the
Liquid Chamber Lid with water, assemble the Lid back in the
machine fixing it by the Fast Lock and continue to process
the products;
10.When processing diferente products, all the parts
that were in contact with the previous product must be
removed from the machine, cleaned and reinstalled.
4.2 Safety System
4.2.1 Sensor to monitor the Liquid Chamber Lid
To provide more safety to the users, this Centrifuge Juicers
CSE has a sensor that avoids the machine to be turned ON
without the Liquid Chamber Lid on its working position.