7. PROBLEM SOLVING
The equipment has been designed to need minimum
maintenance, however, some performance failures may
happen due mainly to natural worn out, caused by the use
of the Processor.
If some problems arise with your Processor check Table - 04
below where there are detailed some possible solutions
PROBLEM
The equipment does not switch
ON.
The equipment stops or slows
down when processing the
product.
The processed product remains
inside the equipment.
Irregular cut.
Burnt smell or smoke.
Damaged cord.
Abnormal noises.
6
TABLE 04
CAUSES
Wrong starting procedure.
Motor thermal protection turned
ON.
Electricity shortage.
Problem with the electric circuit.
The belt is sliding.
The safety device on the lid contact
is failing.
Problem with the electric motor.
The expeller dish is missing.
Off load throat obstructed.
Blunt blades or damaged blades.
Problem with the electric circuit.
Problems with equipment
transportation.
Problem with the bearings.
SOLUTIONS
Read item 3.1 Starting.
Wait some minutes and try again.
Check network.
Call Technical Assistance.
Adjust the belt tension.
Call Technical Assistance.
Place the dish.
Clean the throat.
Change the plate.
Call Technical Assistance.
Call Technical Assistance.
Call Technical Assistance.