- GB -
Water image effect
Air Flo 1.5 kW
Air Flo 4.0 kW
All dimensions are reference values
Float switch installation (C,D)
Place the float switch (3) on the propeller unit (1), turn the float switch (3) clockwise against the stop until the four
fastening flanges (13) are visible. Tighten the float switch (3) using screws (14), washers (15) and nuts (16) to the
fastening flanges (13).
Fitting the spotlight set Lunaqua 10 (optional) (E-L)
Three Lunaqua 10 spotlight sets can be fitted to the Air Flo. The spotlight sets are available as accessories. Ask your
OASE specialist dealer.
Transformer installation (E, F): Ensure that the float switch is NOT fitted. Tighten the transformer (17) using screws
(19), washers (20) and nuts (21) to the transformer mounting plate (18). Tighten the transformer mounting plate (18)
using screws (22), washers (23) and nuts (24) to the propeller unit (1).
Float switch installation (G, H): Place the float switch (3) on the propeller unit (1), turn the float switch (3) clockwise
against the stop until the four fastening flanges (13) are visible. Tighten the float switch (3) using screws (14), washers
(15) and nuts (16) to the fastening flanges (13).
Installation of the Lunaqua 10 lamps (I-L): Connect the plug of the connection cable (27) to the Lunaqua 10 (25), turn in
and firmly tighten the screws (28). Screw the spotlight holder (26) to the Lunaqua 10 (25) using the clamping
screws (29) and square nuts (30). Tighten the spotlight holder (26) to the float switch (3) using screws (31) and wash-
ers (32). Connect three Lunaqua 10 each to one transformer. For this purpose, remove the screws (28) and the cover
cap (33) on the transformer. Connect the plug of the connection cable (27) to the transformer, turn in and firmly tighten
the screws (28).
Avoid kinking the connection cables (Fig. L). If necessary, bundle connection cables with cable binders.
Pos: 58 /Alle Produkte/Überschriften/H1_Aufstellen @ 7\mod_1202907856718_121.doc @ 43934
Installation
Pos: 59 /Pumpen/Schlammsauger/Air Flow LM/Aufstellen Air Flo @ 7\mod_1202908441640_121.doc @ 43986
Air Flo installation (M, N)
The unit floats on the water. Adhere to the minimum water depth. To keep it in position, the enclosed wire cables are
fastened to the unit and either to the bank or to the pond bottom.
Anchoring the unit at the bank (M): Shorten the three wire cables to the desired length. Form loops at the cable ends
(35) and fasten with the cable clamps (36). Hook the cables into the eyebolts (39) at the float switch by means of snap
hooks (34). Knock the three tent pegs (37) into the bank ground. Important: Adhere to the specified bracing angles (40)
to prevent the unit from moving. Set the unit in the water and hook the cables to the tent pegs (37) using the snap
hooks (34). Attention: Pull relieve the connection cable (38) and protect the power plug from moisture!
Anchoring the unit to the pond bottom (N): Shorten the three wire cables to the desired length. Form loops at the cable
ends (35) and fasten with the cable clamps (36). Hook the cables into the eyebolts (39) at the float switch by means of
snap hooks (34). For anchoring to the pond bottom, screw the enclosed threaded hooks (41) including the dowel, for
instance, into three sufficiently heavy stones. Hook three cables with snap hooks (34) in the threaded hooks (41), lower
the stones to the bottom of the pond and set the unit on the water. Attention: Pull relieve the connection cable (38) and
protect the power plug from moisture!
Installation of the control box / motor (overload) protection switch (O)
Install the control box (42) / motor (overload) protection switch (43) at a minimum distance of 2 m from the pond. Fit the
control box (42) such that the connection cables hang down. The control box (42) / motor (overload) protection
switch (43) meet protection type IP 42. For this reason, fit a protective cover over the control box (42) / motor (over-
load) protection switch (43) to prevent the ingress of moisture, if installed outside.
Pos: 60 /Alle Produkte/Überschriften/H1 Inbetriebnahme @ 7\mod_1196625111244_121.doc @ 41417
14
I
Nozzle 138
a [m]
3.5
b [m]
0.8
Nozzle 150
a [m]
6.0
b [m]
1.5
II
Nozzle 120
5.0
1.0
Nozzle 138
8.0
2.0
III
Nozzle 138 and disc 110
6.0
2.0
Nozzle 150 and disc 90
10
3.0