1.5.2.External thermo element
On the right side of the heating plate is the connector for a K-type thermocouple.
NOTE: The K-type thermocouple has +/- polarity. Make sure the polarity is correct here.
If no temperature change is indicated, please check for proper connection.
Insert the K-Type thermocouple connector all the way in and check for proper fit.
1.5. Settings
1.6.1.Change temperature
After switching on, CH0 is displayed. This means that no memory location is
selected. With the
key it is possible to switch between CH1, CH2 and CH3.
An individual temperature or profile can be stored in each of these memory
locations.
The SET temperature (
) can be changed with the +/- keys. The setting
range is 50 - 350 °C.
Press + or - briefly, changes the value by 1°C each time.
Press + or - for a long time, changes the value quickly continuously.
1.6.2.Change parameters
Open menu, other key functions: 1.4. Display and keys