Descargar Imprimir esta página

Quick Tools QU870D Instrucciones De Uso página 23

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
1.6.2.1.Channels
CH1 and CH2 are fixed temperature memories.
CH1 or CH2 can be selected in the Channel menu.
On both memory locations a fast selectable temperature can be stored.
A temperature profile can be programmed on memory location CH3.
T1: The temperature rises to Temp1
S1: Time1, the temperature remains
constant
T2: The temperature rises to Temp2
S2: Time2, the temperature remains constant
It is possible to set 2 temperature zones. Temp1: 50-200°C and
Temp2: 200-350°C.
Under Time1 and Time2 a countdown (0-600 seconds) can be set.
As soon as Temp1 is reached, the countdown (Time1) starts and
counts down the seconds to 0.
After that Temp2 is active and remains constant (Time2).
As soon as the time(Time2) has elapsed, it cools down to Temp1.
The programming must be saved with the
The menu can be exited with the
To start the temperature profile, the heating plate must be switched off and on
again.
key.
key.
7