Insert battery
Open the battery compartment
on the housing's rear side and insert
a 9V battery. Correct polarity must
be observed.
2
Operation
Switch on: Briefly press the On/Off button (4).
Switch off: Keep the On/Off button (4) pressed for 2 seconds.
AutoShutOff: The device will automatically switch itself off
about 30 seconds after the last measurement.
3
Symbols
Red = Live wire warning
AC-SCAN mode
Green = live wire is nearby
Red = live wire found
STUD-SCAN mode
Green/Red: object is nearby
Green: object found
line, object is nearby
4
Calibration
Auto-Calibration
The automatic calibration is performed in AC-SCAN
measurement immediately when the device is switched on
and when the measuring mode is switched. During calibration,
the display shows „CAL". Do not move the device during this
process. Once „CAL OK" appears on the display, tracing
can be started.
StarFinder Plus
line, object found
13