Descargar Imprimir esta página

enphase IQ-EVSE-NA-1040-0100-0100 Manual Del Usuario página 20

Publicidad

Idiomas disponibles

Idiomas disponibles

IQ EV Charger User Manual
WIRING INSTRUCTIONS (Hardwired)
Route the IQ EV Charger conduit to a nearby junction box. Use the
included ½" trade size watertight conduit fitting and sealing washer
to provide a moisture-resistant seal between the conduit fitting
and the junction box. If necessary, drill a ⅞" diameter hole to
accommodate the conduit fitting. Ensure the junction box is fully
sealed for outdoor installations using appropriate electrical grade
silicone sealant.
Figure 6: Wiring the
EVSE in a junction box
Before connecting the service
conductors, carefully read the section of
this manual titled Installation -
Service Connections. If unsure of the type
of power provided at the service panel,
please consult with the local utility or
call a Service Representative for
assistance.
The three supplied IQ EV Charger-40
service conductors use stranded 10 AWG,
90ºC copper wire.
The three supplied IQ EV Charger-50,
IQ EV Charger-60, and IQ EV Charger-80
service conductors use stranded 8 AWG,
90ºC copper wire.
The insulation of each conductor is color-
coded for standard 240 VAC installation:
Green:
Ground
Black:
Line 1 (120 VAC to Ground)
Red:
Line 2 (120 VAC to Ground)
20

Publicidad