IQ EV Charger User Manual
MOUNTING PROCEDURES
Determine the wall mounting position of the EVSE:
•
On the hardwired IQ EV Charger, the three service
conductors are shielded by a 3' (1 m) flexible conduit at
the bottom of the unit. The EVSE must be positioned such
that this conduit can reach a nearby junction box.
•
On the plug-in IQ EV Charger, the NEMA plug head
is connected by up to 6 feet (1.8 m) of cable (including the
plug head) to the bottom side of the EVSE. The plug-in
IQ EV Charger must be positioned such that this plug can
safely be inserted into a wall-mounted NEMA socket.
DO NOT allow the power supply cord to contact the floor
when plugged into the outlet.
•
Position the bottom of the EVSE at a comfortable height and
at least 18" (45.7 cm) above the ground for indoor
installations and 24" (61 cm) off the ground for outdoor
installations. Ensure that the user can see the LEDs on the
front panel of the EVSE of the device.
•
The IQ EV Charger has two vertically aligned mounting
holes spaced 17" (43.2 cm) apart, each on the enclosure's
top and bottom. Use a ruler or template to mark hole locations
on the mounting surface.
WARNING: For safety, always turn off the input power to
the EVSE at the circuit breaker panel before plugging it in or
wiring it to the service lines. Likewise, turn off the circuit
breaker before unplugging it or disconnecting the unit from
the service lines.
24