10. PROTECTION AGAINST DRY RUNNING
If the pump stops running due to lack of water, the Red FAILURE light goes on. To reset the
system, press the RESET button after confirming the presence of water on the suction side or
temporarily disconnect the power supply.
11. AUTOMATIC RESET
Should the pump stop running because of lack of water, the versions with automatic reset
(optional) begin to restart automatically at pre-set intervals of 15, 30 or 60 minutes, depending on
the model. This operation mode is indicated by the rapid flashing of the red indicator light. This
process is repeated until either there is new water available on the suction side of the pump or
else, the pump has reached the maximum number of pre-set retries (2, 4 or 8 depending on the
model). Should this limit be exceeded, the red indicator light remains switched on. To reset the
system, you must press the RESET button after verifying the presence of water on the suction side.
12. MAINTENANCE
The device has been designed to provide maximum performance without the need for special
maintenance during its operational lifespan.
During extended periods of inactivity, particularly during the winter season, the device should be
completely drained of water, in order to prevent it from being
13. TROUBLESHOOTING
PROBLEM
1. The pump does not
deliver any liquid
2. The pump does not
reach the desired
pressure
3. The device stops the
pump from running even
in presence of water
4. The pump does not
start when a tap is
opened
5. The pump starts and
stops frequently
POSSIBLE CAUSE
1. The Fluomac was mounted the
other way round
2. The priming process was not
implemented correctly
3. The suction hose is not properly
immersed in the liquid
1. There are leaks in the system
2. The hose or suction filters are
clogged
3. The foot valve is blocked
1. The pressure is set too high
2. The pump's thermal protection
may prevent the pump from
running
1. The pressure is set too low
1. There are leaks in the system
2. The flow of water from the tap is
too low
damaged..
SOLUTION
1. Check the installation of the
device and correct if necessary
3. Press and hold the RESET
button until the flow is regular
3. Check that the suction hose is
well immersed in water
1. Check for leaks
2. Remove any clogging
3. Replace the foot valve
1. Decrease the pressure until
the problem is resolved.
Contact a professional installer.
2. Check the pump
1. Increase the pressure until the
problem is resolved. Contact a
professional installer
1. Check for any leaks and
resolve as necessary
2. Contact technical support