• Means for disconnection must
be incorporated in the fixed
wiring according with the
wiring rules. An external dis-
connecting device, which will
function as the "designated"
disconnect device must be
provided, and:
1) It shall disconnect the
"Line", while disconnection
of the "Neutral" is optional;
2) Its OFF-position shall be
clearly marked;
3) Not to position the equip-
ment so that it is difficult to
operate it; and
4) The protection current de-
vice must be at least 10A,
250V, curve Type C.
• Exhaust fans may adversely
affect the safe operation of ap-
pliances burning gas or other
fuels (including those in oth-
er rooms) due to back flow of
combustion gases. These gas-
es can potentially result in car-
bon monoxide poisoning. After
installation of an exhaust fan
such as a partition fan or a duct
fan the operation of flued gas
appliances should be tested by
a competent person to ensure
that back flow of combustion
gases does not occur (AS/NZS
60335.2.80:2016/A1:2020)
SAFETY DURING INSTALLATION
Fan unit equipment should be electrically isolated
and locked out before any work started.
The Installer, User is responsible for ensuring that the
fan unit is installed, operated and serviced by qual-
ified personnel, acting in accordance with all safety
precautions applicable and as required by law, regula-
tions and standards in the country applicable.
Safety protective clothing, equipment, hearing protec-
tion, and tools may be required.
Before any installation work is started, ensure that fan
unit equipment is correct for application. Location for
installation is solid, level, flat and suitable for mount-
ing fan unit assembly.
Fan unit should be located in position, and assembled
with any accessory equipment supplied, on relevant
mounting, anti-vibration mountings, safety protection
guards, on a solid level base to avoid any distortion
and misalignment and with correct air direction as
shown on nameplate. Fan unit should then be levelled
on any anti-vibration mountings. Flexible connectors
must be taught to ensure no disruption to air flow, es-
pecially on inlet to fan unit.
Make sure there are no loose elements near the fan
unit. When the fan unit is mounted in a duct, check
that it is clean of any elements and exclusively used
for ventilation system.
The electrical installation must include a double pole
switch with a contact clearance of at least 3 mm,
correctly sized and in accordance with the electrical
standards of the country of installation.
For electrical connections follow the wiring diagram
"A" indicated in this manual.
The fan unit classified as Residential Ventilation Unit
with control factor 0,65 have to comply with the re-
quirements of the European Directive 2009/125 and
must be installed following the local demand control
definition given in the regulation nº1253/2014 (See
fig.B as example).