Descargar Imprimir esta página

Levenhuk Ermenrich Zing TC33 Guia Del Usuario página 4

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
Temperature measurement
AC/DC current measurement
Smart (Automatic) mode
Automatic power off
Low battery indicator
OL
Overload indication
Input polarity indication
– – – L
Weak electric field signal indication
– – – H
Strong electric field signal indication
User must refer to the safety instructions and user
manual.
Smart (Auto) measurement mode
The multimeter is turned on in Smart (Auto) measurement mode by default. In this mode, DC voltage, AC voltage, resistance, and continuity
can be measured, and the multimeter can automatically identify the measurement signal.
Plug the black test lead into the COM jack (8) and the red test lead into the INPUT jack (9). Connect the probes to the measuring points or in
parallel to the circuit to be measured. The multimeter will automatically recognize the measured signal. If the resistance is <50Ω, an acoustic
signal will be emitted continuously. The measurement results will appear on the VA display (6).
Professional (Manual) measurement mode
AC/DC voltage measurement
Press the FUNC button (3) to select the function. Press the SEL button (2) to select AC voltage or DC voltage. The
is displayed accordingly. Plug the black test lead into the COM jack (8) and the red test lead into the INPUT jack (9). Connect the probes to
the measuring points. The measurement results will appear on the VA display (6).
Resistance measurement
Press the FUNC button (3) to select the
jack (9). Connect the probes to the resistance measuring points of circuit or resistor. The measurement results will appear on the VA
display (6).
Continuity test
Press the FUNC button (3) to select the
jack (9). Connect the probes to the circuit or component to be tested. The measurement results will appear on the VA display (6). If the
resistance is <50Ω, an acoustic signal will be emitted continuously.
AC/DC voltage measurement (in mV)
Press the FUNC button (3) to select the
is displayed accordingly. Plug the black test lead into the COM jack (8) and the red test lead into the INPUT jack (9). Connect the probes to
the measuring points. The measurement results will appear on the VA display (6).
Frequency and duty cycle measurement
Press the FUNC button (3) to select the
jack (9). Connect the probes to the measuring points or in parallel to the circuit to be measured. The measurement results will appear on the
VA display (6).
Capacitance measurement
Press the FUNC button (3) to select the
jack (9). Connect the probes to the capacitance to be measured. The measurement results will appear on the VA display (6).
Diode test
Press the FUNC button (3) to select the
jack (9). Connect the black test probe to the cathode side and the red test probe to the anode side of the diode to be measured. If the polarity
of the test probes is reverse to the diode polarity, the OL (Overload) will appear on the screen. This can be used for distinguishing the anode
and cathode side of a diode. The measurement results will appear on the VA display (6).
Temperature measurement
Press the FUNC button (3) to select the
lead into the INPUT jack (9). Connect the thermocouple probe to the object to be measured. The measurement results will appear on the VA
display (6).
AC/DC current measurement
Press the FUNC button (3) to select the
symbol is displayed and the multimeter enters the DC current measurement mode. Press the SEL button (2) to display the
and enter AC current measurement mode. Plug the red test lead into the A jack (7) and the black test lead into the COM jack (8). Disconnect
the measured power supply, connect the multimeter in series with the power supply, and then turn on the measured power supply. The
measurement results will appear on the VA display (6).
function. Plug the black test lead into the COM jack (8) and the red test lead into the INPUT
function. Plug the black test lead into the COM jack (8) and the red test lead into the INPUT
function. Press the SEL button (2) to select AC voltage or DC voltage. The
function. Plug the black test lead into the COM jack (8) and the red test lead into the INPUT
function. Plug the black test lead into the COM jack (8) and the red test lead into the INPUT
function. Plug the black test lead into the COM jack (8) and the red test lead into the INPUT
function. Plug the black test lead of K-type thermocouple into the COM jack (8) and the red test
function. Or insert the red probe into the A jack (7) to automatically select the
4
symbol or
symbol
symbol or
symbol
function. The
symbol

Publicidad

loading

Este manual también es adecuado para:

82990