Continuity Test; Diode Test; Capacitance - ADInstruments AD71B Manual De Usuario

Multímetro digital
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

_____________________________________________________________________
c)
A residual reading of 80 digits with test leads shorted, will not affect stated
accuracy.
d)
When frequency is lower than 100kHz, the accuracy guarantee range
10%-100%.
e)
When making AC+DC measurment, the accuray need to add (1%+ 35 digits)
of reading based on the above table.
z At 10A range:
a) When the measured current is ≤ 5A, continuous measurement is allowed.
b) When the measured current is between 5A-10A, continuous measurement ≤ 10
seconds and interval more than 15 minutes.
E. Resistance
Resoluti
Range
on
200
0.01
2k
0.0001k
20k
0.001k
200k
0.01k
2M
0.0001M
20M
0.001M
F. Continuity Test
Range Resolution
0.01
Remarks:
z Open circuit voltage approximate -1.2V.
z The buzzer does not sound when the test resistance is
z The beeper comes on continuously for open conditions, that is test resistance is
≤ 40 .
G. Diode Test
Range Resolution
0.0001V
Remarks:
Open circuit voltage approximate 2.8V.
z
A good silicon junction drops between 0.5V and 0.8V.
z
H. Capacitance
Range Resolutio
©Copyright Abacanto Digital SA.
Accuracy
UT71A
±(0.5%+20)+t
±(0.4%+20)+t
est leads open
est leads open
circuit value
circuit value
±(0.5%+20)
±(0.4%+20)
±(1%+20)
±(0.8%+20)
±(1%+40)
±(1%+40)
±(1.5%+40)
±(1.5%+40)
Overload
Protection
1000V
Overload
Protection
1000V
Accuracy
Manual de usuario AD71B
Overload
UT71B
Protection
1000V
Overload
AD Instruments
60 .
71

Publicidad

Tabla de contenido
loading

Tabla de contenido