- EN -
Set-up and start-up
The unit is supplied fully assembled as a complete set containing three spotlights, including light bulbs (A1).
Attention – Risk of fire! When set up above the water level, maintain a safety distance of at least 50 cm from
combustible material. Do not cover the unit.
Position the unit such that it does not present a hazard for anybody. Ensure a safe seating. Connect the power plug of
the spotlight to the socket of the transformer/transformer supply cable (A2). Connect the transformer plug to the mains
socket (A3) and check the spotlight function.
Replacing the lamp glass and the bulb
Adhere to the safety instructions! Disconnect the power! Press the lamp out of the decorative rock from the rear (B5),
remove residual water. Ensure that no moisture can enter the unit. Unscrew union nut (B1), remove glass (B2) and O
ring (B3), check and, if necessary, replace, remove the bulb (B4) from the housing.
Insert new bulb (do not touch, use a cloth or similar). Reassemble the unit in the reverse order. The lamp is fixed in the
decorative rock by means of the rubber ring (B5). Reconnect to the power supply and check function.
S
Malfunctions
Malfunction
Lamp does not light up
Light intensity decreases
Water in the spotlight housing
Maintenance and cleaning
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
If necessary, clean the unit with clear water using a soft brush.
• Ensure that no moisture can enter the unit.
Wear parts
• Bulb
• Seals
Repair
Neither the transformer nor the spotlights can be repaired in the event of damage to the cables or the housing and
have to be replaced.
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
Guarantee conditions
PfG grants a 2 year guarantee from the date of sale on proven material and manufacturing faults. Prerequisite for our
guarantee is the presentation of the purchase receipt. Our guarantee will become null and void if the unit is misused,
electrically or mechanically damaged by inappropriate use and improper repair by non-authorised workshops. Repairs
are reserved for workshops authorised by PfG or by PfG itself. In the case of warranty claims, please return the defec-
tive unit or part freight paid to PfG together with a description of the fault and the purchase receipt. PfG reserves the
right to invoice repair costs. PfG is not liable for transport damage. Any damage must be claimed against the carrier.
Further claims of whatever type, especially consequential damage, are excluded. This guarantee does not affect the
final customer's claims against the dealer.
8
Cause
Power supply interrupted
Bulb defective
Contact pins at the bulb corroded
Lamp glass soiled
Seal defective
Remedy
Check power supply
Replace bulb
Clean contact pins
Clean
Check sealing rings and replace, if necessary