M-Audio OXYGEN61 Manual Del Usuario página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Advanced Keyboard Functions
Edit Button: The Edit button is used to access the advanced Oxygen 61 functions located on the keybed. Pressing the Edit
button switches your keyboard into Edit Mode. You can use the keys to select various advanced functions and enter data.
To change the functionality of a fader, button, knob, etc.:
1.
Press the Edit button.
2.
Press the Select button or Control Select (Ctrl Sel) key.
3.
Move or press the control corresponding to the control you would like to change or using the keys, enter the numerical
value of the control number.
4.
Press the corresponding key of the parameter you would like to change (Ctrl Asgn, Data 1, Data 2, etc.)
5.
Use the numeric keys to enter the value of the parameter.
Snapshot: Press the Shift button and the Auto button simultaneously to engage the Snapshot function. The Snapshot function
sends out the assigned MIDI Message and current value of all controls on the MIDI channel that a control is set to. This feature
lets you record current settings of the controls into your sequencer.
DirectLink Mode: Press the Auto button to go into DirectLink Mode. Knobs, buttons, < and >, and faders will send pre-
programmed automapped messages. None of these parameters can be edited while in DirectLink Mode. For some DAWs and
programs, you may need to download DirectLink profiles from m-audio.com/directlink.
Control Assign, Data 1, Data 2, Data 3: The Control Assign function (Ctrl Asgn) assigns a MIDI continuous control number
(MIDI CC) or other MIDI parameter to the selected knob, button, wheel, fader, or to the sustain pedal. The Data 1, Data 2, and
Data 3 keys define various related aspects of the parameter or function assigned to a control.
Channel Assign: The Channel Assign function (Chan Asgn) assigns a knob, fader, button, wheel, or the sustain pedal to a
specific MIDI channel.
1.
Press the Edit button.
2.
Press the Select button or Control Select (Ctrl Sel) key.
3.
Select the control as described earlier in this guide.
4.
Press the Channel Assign (Chan Asgn) key. The LED display will show the currently assigned MIDI channel for the active
control (for example, "c.0.2.").
5.
Enter the new MIDI channel number using the number keys.
6.
Press the Enter key.
When assigned to channel "0", the control (knob, fader, button, wheel, or sustain pedal) will transmit on the Global MIDI
Channel. See the next section, "Global Channel" for more information.
NOTE: When a control is assigned to send SysEx messages, the displayed number represents the SysEx Device ID instead of
the MIDI transmit channel number.
Global Channel: The Global Channel function (Global Chan) sets the default MIDI channel for the keyboard and all MIDI
controls, except for those that have a specific MIDI channel assigned to them.
1.
Press the Edit button.
2.
Press the Global Channel (Global Chan) key. The LED display will show the current Global channel. For example, if
channel 1 is the current Global channel, it will appear as "c.0.1".
3.
Enter the new channel number using the number keys.
4.
Press the Enter key.
The Global Channel can also be changed by using the following method:
1.
Press the Select button until the lower edge of the LED displays a red dot above "Global".
2.
Scroll through the MIDI channels using the < or > buttons to select the new channel number.
Program: This function sends Program Change MIDI messages on the Global Channel and can be used to select different
sound presets contained within your virtual instrument or sound module.
1.
Press the Edit button.
2.
Press the Program key. The LED display will show the last sent program number (for example, ".0.1.").
3.
Enter the Program number.
4.
Press the Enter key to send the program change message.
Program Change messages can also be sent using the following method:
1.
Press the Select button until the lower edge of the LED shows a red dot above "PGM".
2.
Scroll through the Program numbers using the < or > buttons.
Bank LSB: The Bank LSB function sends bank change messages on the Global MIDI channel. These messages are used to
access additional banks of sound presets on virtual instruments or sound modules (if additional banks are available). Refer to
the documentation for the virtual instrument or synthesizer to confirm it will respond to these messages.
1.
Press the Edit button.
2.
Press the Bank LSB key. The LED display will show the last sent Bank LSB number (for example, ".0.1.").
3.
Enter the new Bank LSB number using the number keys.
4.
Press the Enter key.
6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Oxygen 61 mkivOxygen 49 mk4Oxygen 61 iv

Tabla de contenido