Velleman DVM1500 Manual Del Usuario página 10

Ocultar thumbs Ver también para DVM1500:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
continuously and the resistance value is displayed. If the measured
resistance exceeds the current range or in case of an open circuit, the
display shows "OL".
Note: Never perform continuity measurements on a live circuit and make
sure all capacitors are completely depleted.
Diode Measurements
Do not perform diode measurements on live circuits.
1. Connect the red test lead to "VΩ
the "COM" jack.
2. Set the rotary switch to
3. Press the FUNC button to select diode test
4. Connect the red test probe to the anode of the diode and the black test
probe to the cathode.
The meter displays the forward voltage drop of the diode. If the diode is
connected with a reversed polarity, the meter displays "OL".
Notes
Never perform diode measurements on a live circuit and make sure all
capacitors are completely depleted.
Measuring diodes that are part of a circuit might produce faulty results.
Consider unmounting from the circuit.
Capacitance Measurements
Do not perform capacitance measurements on live circuits.
1. Connect the red test lead to "VΩ
the "COM" jack.
2. Set the rotary switch to
3. Press the RANGE button to manually select the range.
4. Connect the test probes to the capacitor and read its value from the
display.
Notes:
Depending on the capacitance, the meter needs 5 to 30 seconds to show
the result. This is normal behaviour.
To increase accuracy when measuring low capacitance values (< 4 nF), first
hold the tips of the test probes together to determine the capacitance value
of the test leads. Subtract this value from the measured value of the circuit.
Never perform capacitance measurements on a live circuit and make sure
all capacitors are completely depleted.
Frequency Measurements
Do not perform frequency measurements in circuits with
voltages > 250 V.
V. 03 – 04/11/2013
DVM1500
°CHz" jack and the black test lead to
.
°CHz" jack and the black test lead to
.
10
.
©Velleman nv

Publicidad

Tabla de contenido
loading

Tabla de contenido