Lamborghini Caloreclima EM 3-E Manual Para La Instalación Y El Mantenimiento página 41

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

PRESSURE CURVES - B/P GAS DELIVERY
EM 3-E
Thermal output
Legend
Pi Inlet pressure (combustion head + gas train)
Pt Pressure at combustion head
MAINTENANCE
Skilled staff has to perform yearly the following operations:
- Check the valve inside tightness.
- Filter cleaning.
- Fan and head cleaning.
- Check the position of the ignition electrode tips as well as the control
electrode.
- Calibrate the air and gas pressure switches.
- Check the combustion by means of CO2-CO-FUMES TEMPERATURE
bearings.
- Check all the gaskets and seal tightness.
To gain access to the main components, remove the cover, as shown in
(Fig.1).
Combustion head maintenance should be made as follows:
- Close the gas cock and disconnect the gas train. Unscrew the screws 1
and remove the cover 2 (fig.1).
- Unscrew the screws 3 and the central pin 4 (fig.2).
- Hang the component holder plate into the service position 5 and effect
combustion head maintenance (fig.3).
EM 6-E
Thermal output
- 41
-
EM 9-E
Thermal output
fi g.1
fi g.2
fi g.3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Em 6-eEm 9-e

Tabla de contenido