ENGLISH
1
Carrying handle
2
Sub-table
3
Bolt or screw
4
Pilot lamp
5
Switch
6
Crank handle
7
Scale
8
Main frame
9
Indicator plate
10 Depth gauge
11 Groove
12 Depth adjusting gauge
13 Stopper
14 Stopper button
15 Stopper knob
16 Table top
17 Lock plate
18 Pulley
SPECIFICATION
Model
Cutting width
Max. cutting depth
Feed rate (min
Table size (W x L)
No load speed (min
Overall length (W x L x H)
Net weight
safety class
• Due to our continuing program of research and devel-
opment, the specifications herein are subject to change
without notice.
• Note: Specifications may differ from country to country.
Intended use
The tool is intended for planing wood.
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and can
only be operated on single-phase AC supply. They are
double-insulated in accordance with European Standard
and can, therefore, also be used from sockets without
earth wire.
Explanation of general view
19 Drum
20 Chain
21 Thumb screw
22 Blade installation bolt
23 Set plate
24 Blade
25 Claw
26 Magnetic holder
27 Socket wrench
28 Blade installation bolt
29 Screw
30 Blade gauge
31 Hood set
32 Chip cover
33 Rubber cap
34 Leg
35 Stay (B)
36 Stay (A)
–1
)
–1
)
37 Hex nut
38 Spring washer
39 Cap square neck bolt
40 Hex bolt
41 Flat washer
42 Bolt
43 Ruler
44 Post card
45 Adjusting screw
46 Hex wrench
47 Limit mark
48 Brush holder cap
49 Screwdriver
50 Column
51 Base
52 More than 4 mm
2012NB
304 mm
3.0 mm of stock width less than 150 mm
1.5 mm of stock width from 150 mm to 240 mm
1.0 mm of stock width from 240 mm to 304 mm
8.5 m
304 mm x 771 mm
8,500
483 mm x 771 mm x 401 mm
27 kg
For public low-voltage distribution systems of
between 220 V and 250 V
Switching operations of electric apparatus cause voltage
fluctuations. The operation of this device under unfavor-
able mains conditions can have adverse effects to the
operation of other equipment. With a mains impedance
equal or less than 0.38 Ohms it can be presumed that
there will be no negative effects.
The mains socket used for this device must be protected
with a fuse or protective circuit breaker having slow trip-
ping characteristics.
Safety hints
For your own safety, please refer to the enclosed safety
instructions.
/II
7