Conditions for usage and installation

Necessary preparatory work at the customer's premises are to be arranged by the
machine operator. The work must be carried out by authorised installation technicians
in compliance with general, country-specific and local regulations. The WMF service
engineers may only connect the machine to existing prepared connection points. WMF
Service is neither authorised nor responsible for carrying out any work on-site prior to
connection.
Mains voltage tolerance
range
Ambient temperature
Maximum humidity
Degree of protection
Installing surface
Installation clearances
Ventilation
These specifications for the electrical connection and the standards quoted apply for connecting the
machine in EU countries. It may be necessary to also observe additional country-specific regulations.
Outside the EU countries acceptance of the standards quoted is to be checked by the legal entity or
natural person who wishes to use the machine.
The local power supply must be constructed according to IEC 364. To improve safety, the
coffee machine should be fitted with an FI 30 mA earth leakage current circuit breaker
complying with EN 61008. Near the device or about 30 cm below the counter top there should
be a shockproof socket as a single-phase connection installed locally on the rear or side wall
of the counter substructure or a country-specific single-phase socket. The socket is part of
the customer's on-site installation. The mains cable must not come into contact with hot
surfaces. If the mains cable for this device is damaged then it must be replaced by our service
personnel or a similarly qualified person, in order to prevent hazards.
User Manual WMF Cooler
230 V +10 % and -10 %,
Mains voltage interruption < 50 ms: no interruption of function
+16 °C to max. +32 °C
80 % relative humidity without condensation.
Do not use unit outdoors.
IP X0
The unit must be placed on a level, flat, and sturdy surface.
The unit is not intended to be located on a surface that is sprayed
or cleaned with a water hose, steam jets, steam cleaner, or similar
devices.
For operating, service and safety reasons the machine should
be installed with a clearance of no less than 50 mm between
the back of the machine and the wall. If possible, there should
be a clearance of 50 mm to the sides. (Lateral connection WMF
coffee machine and WMF cooler not taken into account.)
If the possibility of ventilation is limited, adequate ventilation
must be provided. Ventilation must be designed according to the
installation situation. (e.g. machine on legs, active ventilation,
additional air vents / openings in counter area, etc.). Ventilation
openings must not be covered.