6. Commissioning, operation / 7. Maintenance and cleaning
WARNING!
Only open the connections once the system has been depressurised
■
Observe the working conditions in accordance with chapter "3. Specifications".
■
Always operate the pressure transmitter within the overpressure safety range!
■
WARNING!
When touching the pressure transmitter, please note that the surfaces of the instrument
components can become hot during operation.
6.4 Accessories
Accessories can be found online at www.festo.com/catalogue.
7. Maintenance and cleaning
7.1 Maintenance
This instrument is maitenance-free. Repairs must only be carried out by the manufacturer.
7.2 Cleaning
CAUTION!
Before cleaning, correctly disconnect the instrument from the pressure supply, switch it off and
■
disconnect it from the mains.
Clean the instrument with a moist cloth.
■
Wash or clean the dismounted instrument before returning it in order to protect personnel and
■
the environment from exposure to residual media.
Residual media in dismounted instruments can result in a risk to persons, the environment and
■
equipment. Take sufficient precautionary measures.
Do not use any pointed or hard objects for cleaning, since the diaphragm of the process
■
connection must not be damaged.
For information on returning the instrument see chapter „9.2 Return".
Pressure transmitter SPTW
EN
13