Greenlee GT-220 Manual De Instrucciones página 16

Verificadores eléctricos
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Accuracy (cont'd)
600 Ohm with Beeper (GT-540 only)
Range
600.0 Ω
* ± (2.0% + 3.6 Ω) below 120 Ω
Beeper response time: 100 µs
Beeper on: R < 50 Ω typical; 250 Ω max
Open circuit voltage: 0.4 Vdc typical
Diode Test with Beeper (GT-540 only)
Range: 1.000 V
Beeper response time: 100 µs
Open circuit voltage: < 1.6 Vdc typical
Test current: 0.25 mA typical
Capacitance (GT-540 only)
Range
100.0 nF*
1000 nF
10.00 µF
100.0 µF
2000 µF
* Accuracy not specified below 50 nF.
The accuracy specification is for capacitors that have negligible dielectric
absorption, or film capacitors.
16
Accuracy
± (2.0% + 0.6 Ω)*
Accuracy
± (3.5% + 0.5 nF)
± (2.5% + 2 nF)
± (2.5% + 0.02 µF)
± (2.5% + 0.2 µF)
± (2.5% + 5 µF)
Maximum
Measurement Time
2.5 s
2.5 s
5 s
8 s
85 s

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gt-540

Tabla de contenido