10. PROBLEMS AND SOLUTIONS
10.1.
Problem-Cause-Solution Chart
Problem
Dryer does not start
Dryer does not heat up
If the dyer does not dry
adequately
(1) To reset the security thermostat, open the black plastic cap in the rear panel and push the
button. Close the cap and re-start. If the problem persists, connect our after sales team.
(2) To reset the gas alarm, press the black button in the rear panel of the machine. If the
problem persists, connect our after sales team.
Should any other doubts arise, please do not hesitate to contact our after sales team.
DTA-DTP-11-18-27_Manual_ML
Cause
Time set to 0
Door open
Filter cover open
Micro cover/door not
working
Emergency button
No electricity supply
Timer on Cooldown
Heater doesn't receive
ON signal
Gas alarm
Insufficient steam
pressure
Insufficient time of cycle
Insufficient air flow
Solution
Select correct time
Close door
Close filter cover
Change micro-cover or door
Turn ¼ revolution to disconnect
Check main switch is ON
Check fuses are OK
Check Manis voltaje is correct
Increase selected time
Check thermostat / Electronic control
plate
Check safety thermostat. (1)
Reset the alarm (2)
Turn on steam boiler
Increase time of cycle
Clean lint filter
Check blow off pipe is clean and not
blocked.
Clean extractor-fan blades
Blow off pipe too long
Check the room has enough fresh air
ventilation.