INSTALLATION INSTRUCTIONS
Step 2: Install the drain joint
Before bolting the outdoor unit in place, install the drain joint at the bottom of the unit. There are two types of
drain joint depending on the type of unit.
1. Fit the rubber seal on the end of the drain joint that will connect to the outdoor unit.
2. Insert the drain joint into the hole in the base pan of the unit.
3. Rotate the drain joint 90° until it clicks in place facing the front of the unit.
4. Connect a drain hose extension (not included) to the drain joint to redirect water from the unit during
heating mode.
The base hole for the drain joint can be found on the bottom of the unit.
Note For Cold Climates
In cold climates, ensure that the drain hose is positioned as close to vertical as possible to encourage swift
water drainage. If water drains too slowly it can freeze inside the drain hose and fl ood the unit.
18