INSTALLATION INSTRUCTIONS
INSTALLATION SUMMARY
When installing multiple indoor units to a single outdoor unit, ensure that the length of the refrigerant pipe
and the drop height between the indoor and outdoor units meet the following requirements:
Indoor Unit
Indoor units that can be used in combination Number of connected units 1 - 5 units
Compressor stop/start frequency
Power source voltage
Units are in meters/feet
Max. length for all rooms
Max. length for one indoor unit
Max. height difference between indoor and outdoor
Max. height difference between indoor units
Outdoor Unit
Outdoor Unit
Outdoor Unit
Stop time
Voltage fl uctuation
Voltage drop during start
Interval unbalance
1 drive 2 1 drive 3 1 drive 4 1 drive 5
40/131
25/82
15/49
10/33
4
49ft (15m)
32.8ft (10m)
49ft (15m)
3 minutes or more
within ± 10% of rated voltage
within ± 15% of rated voltage
within ± 3% of rated voltage
60/197
80/262
30/98
35/115
15/49
15/49
10/33
10/33
80/262
35/115
15/49
10/33